Acumen Hypotension Prediction Index (HPI) Feature Software
Quick answers
What is Acumen Hypotension Prediction Index (HPI) Feature Software?
Acumen Hypotension Prediction Index (HPI) Feature Software: The leading global structural heart innovation company. Made by Edwards Lifesciences.
Is Acumen Hypotension Prediction Index (HPI) Feature Software FDA cleared?
Yes. Acumen Hypotension Prediction Index (HPI) Feature Software is on FDA’s list of AI-enabled medical devices: De Novo DEN160044, granted March 16, 2018.
Overview
Acumen Hypotension Prediction Index (HPI) Feature Software Overview
The Acumen Hypotension Prediction Index (HPI) software by Edwards Lifesciences is an advanced, predictive monitoring technology designed to alert clinicians to the likelihood of a patient trending toward a hypotensive event before it occurs. Utilizing machine learning algorithms, the HPI software analyzes complex blood pressure waveform features to provide a unitless score ranging from 0 to 100, indicating the probability of hypotension (defined as mean arterial pressure < 65 mmHg for at least one minute) within a specified timeframe, typically 15 minutes.
This innovative software is integrated into Edwards’ advanced hemodynamic monitoring platforms, such as the HemoSphere system. It is compatible with both invasive arterial line monitoring (e.g.
Beyond simply predicting an event, the Acumen HPI software provides a ‘Relationship View’ screen that offers insights into the potential underlying causes of hypotension, visually arranging hemodynamic parameters by preload, afterload, and contractility. This feature, combined with ‘Smart Alerts’ and ‘Smart Trend’ screens, supports clinicians in making proactive, goal-directed therapeutic decisions to address hemodynamic instability and potentially reduce the incidence, duration, and severity of intraoperative hypotension.
Clinical studies have demonstrated that the use of Acumen HPI software can significantly reduce the duration of intraoperative hypotension and is associated with improved patient outcomes, including a reduced risk of complications such as acute kidney injury and myocardial injury.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- Hypotension Prediction Index (HPI) parameter (0-100 score)
- Smart Alerts and Smart Trend screen for impending hypotensive events
- Relationship View screen providing insights into preload, afterload, and contractility
- Machine learning algorithms for predictive analysis of blood pressure waveforms
- Predicts hypotension up to 15 minutes before an event
- Demonstrated reduction in incidence, duration, and severity of intraoperative hypotension
- Compatibility with both invasive (arterial line) and non-invasive (Acumen IQ cuff) monitoring
- Adjustable Mean Arterial Pressure (MAP) target for hypotension definition
- Supports goal-directed hemodynamic therapy (GDHT)
Use Cases
- Proactive management of intraoperative hypotension in surgical patients
- Early detection of hemodynamic instability in critical care settings
- Guiding individualized goal-directed hemodynamic therapy
- Reducing the risk of postoperative complications associated with hypotension (e.g., AKI, MI)
- Retrospective analysis of hemodynamic data for quality improvement (via Acumen Analytics)
What Physicians Need to Know
The Acumen HPI software serves as a valuable decision support tool for proactively managing hypotension in surgical and non-surgical settings. It provides an index (0-100) indicating the likelihood of a hypotensive event, with higher values signifying increased risk. When an alert is triggered, utilize the secondary screen to investigate underlying hemodynamic parameters like preload, afterload, and contractility to determine the root cause and guide appropriate interventions. While powerful for prediction, remember that the HPI parameter is for reference only and should not be the sole basis for therapeutic decisions; always integrate it with other clinical information and patient assessment.
The Acumen HPI Feature Software is designed to integrate with Edwards Lifesciences' HemoSphere advanced monitoring system. It utilizes data from the Acumen IQ sensor (minimally invasive, connecting to an existing radial arterial line) or the non-invasive Acumen IQ cuff to continuously calculate and display hemodynamic parameters. The HemoSphere monitor can also be used with other non-invasive sensors for additional parameters like peripheral or cerebral saturation.
Details
| Category | Cardiology AI, Triage & ER/ICU AI |
| Pricing | Unknown |
| Compliance | |
| BAA Available | Unknown |
| HIPAA Compliant | Yes AI-estimated |
| FDA Status | Authorized FDA-listed |
| Integrations | |
| EHR | Not specified |
| Specialties | Anesthesiology, Critical Care, Emergency Medicine |
FDA clearance history
This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.
| Decision date | Number | Name as listed by FDA |
| 2018-03-16 | DEN160044 De Novo | Acumen Hypotension Prediction Index (HPI) Feature Software |
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate Acumen Hypotension Prediction Index (HPI) Feature Software
Videos
Product demos, reviews, and walkthroughs for Acumen Hypotension Prediction Index (HPI) Feature Software.
No videos found. Search YouTube directly
Frequently Asked Questions
Compare Acumen Hypotension Prediction Index (HPI) Feature Software
VS
VS
VS
VS








