Monaco RTP System (6.3)
Overview
The Monaco RTP System (6.3) is a sophisticated AI-powered treatment planning system for radiation therapy, developed by Elekta Solutions AB. It utilizes the Monte Carlo algorithm, recognized for its accuracy in dose calculation, to create high-quality treatment plans for various radiotherapy techniques, including 3D CRT, IMRT, VMAT, SRS, and SBRT. The system incorporates multicriterial optimization (MCO) to spare organs at risk while maintaining target coverage, and its Predictive Insights tools facilitate real-time interaction during optimization for efficient decision-making. Monaco features a user-friendly interface designed to guide users through advanced features, aiming to create accurate plans efficiently. It integrates innovative biological cost functions, a powerful leaf-sequence optimizer, and a robust Monte Carlo dose calculation algorithm to provide an advanced IMRT planning solution. The system is vendor-neutral, supporting major linear accelerators and connecting to various record-and-verify information systems. Monaco also offers automated contouring processes with deformable image registration for accelerated adaptive therapy and retreatments.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- Monte Carlo algorithm for accurate dose calculation
- Multicriterial optimization (MCO)
- Predictive Insights tools for real-time optimization
- User-friendly interface
- Automated contouring with deformable image registration
- Support for 3D CRT, IMRT, VMAT, SRS, and SBRT
- Vendor-neutral platform
- Integration with MOSAIQ oncology information system
- API-based scripting for automation
- Biological cost functions
Use Cases
- Radiation treatment planning for various cancer types
- Intensity Modulated Radiation Therapy (IMRT)
- Volumetric Modulated Arc Therapy (VMAT)
- Stereotactic Radiosurgery (SRS)
- Stereotactic Body Radiotherapy (SBRT)
- Proton therapy planning
Details
| Category | Clinical Decision Support & Reference, Oncology AI, Radiology & Imaging AI |
| Pricing | Unknown |
| Deployment | On-premise (Windows operating system, off-the-shelf computer server/hardware) |
| Compliance | |
| BAA Available | Yes AI-estimated |
| HIPAA Compliant | Yes AI-estimated |
| FDA Status | Cleared AI-estimated |
| Integrations | |
| EHR | Not specified |
| Specialties | Oncology, Radiology |
FDA clearance history
This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.
| Decision date | Number | Name as listed by FDA |
| 2026-02-19 | K252002 510(k) | Monaco RTP System (6.3) |
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate Monaco RTP System (6.3)
Videos
Product demos, reviews, and walkthroughs for Monaco RTP System (6.3).
No FAQs available yet for this tool.







