Cobalt XT MRI ICD (DDPA2D1, DDPA2D4, DVPA2D1, DVPA2D4)
Overview
The Medtronic Cobalt XT MRI ICD (models DDPA2D1, DDPA2D4, DVPA2D1, DVPA2D4) is an implantable cardioverter-defibrillator (ICD) designed to monitor and regulate heart rate and rhythm. These devices are intended for the automated treatment of patients at significant risk of developing atrial and/or life-threatening ventricular arrhythmias through antitachycardia pacing, cardioversion, and defibrillation therapies. The Cobalt XT ICDs feature advanced algorithms to manage atrial fibrillation (AF), deliver 40 J energy on the first and subsequent shocks, and offer extended longevity. They are enabled with BlueSync™ technology for tablet-based programming and app-based remote monitoring, and are compatible with an automated heart failure risk stratification tool. The PhysioCurve™ design aims to reduce skin pressure and enhance patient comfort. The Cobalt XT MRI ICDs are MR Conditional, allowing patients to undergo 1.5T or 3T full-body MRI scans when used with Medtronic/Vitatron MRI compatible leads and under specified conditions.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- BlueSyncu2122 Technology
- SmartShocku2122 2.0+ Technology
- Intrinsic ATPu2122 (iATP) algorithm
- Reactive ATPu2122 (rATP) algorithm
- TruAFu2122 detection algorithm
- OptiVolu2122 2.0 fluid status monitoring
- TriageHFu2122 technology
- PhysioCurveu2122 design
- MRI SureScanu2122 (1.5 and 3T)
- 40 J energy available on first and every shock
Use Cases
- Automated treatment of atrial and/or life-threatening ventricular arrhythmias
- Cardiac resynchronization therapy (CRT) for heart failure patients with ventricular arrhythmias
- Continuous monitoring of heart rhythm
- Delivery of antitachycardia pacing, cardioversion, and defibrillation therapies
- Remote monitoring and programming by clinicians
- Heart failure risk assessment
Details
| Category | Cardiology AI, Wearables & Remote Monitoring (RPM) |
| Pricing | Unknown |
| Deployment | Implantable device |
| Compliance | |
| BAA Available | Unknown |
| HIPAA Compliant | Unknown |
| FDA Status | Cleared AI-estimated |
| Integrations | |
| EHR | Not specified |
| Specialties | Cardiology, Critical Care, Radiology |
FDA clearance history
This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.
| Decision date | Number | Name as listed by FDA |
| 2025-10-28 | P980016/S939 PMA | Cobalt XT MRI ICD (DDPA2D1, DDPA2D4, DVPA2D1, DVPA2D4) |
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate Cobalt XT MRI ICD (DDPA2D1, DDPA2D4, DVPA2D1, DVPA2D4)
Videos
Product demos, reviews, and walkthroughs for Cobalt XT MRI ICD (DDPA2D1, DDPA2D4, DVPA2D1, DVPA2D4).
No FAQs available yet for this tool.