iCAC Device vs ElucidVivo A.3

Similar category, different focus. These tools serve overlapping but distinct needs. Comparability 65/100 Comparability is an AI-graded 0–100 score of how directly these two tools compete — higher means a more apples-to-apples comparison.
by Bunkerhill Health
VS
by Elucid

AI Verdict

Tool A, the iCAC Device, focuses on the opportunistic detection and quantification of coronary artery calcium from routine, non-contrast CT scans for early cardiovascular disease risk assessment. In contrast, Tool B, ElucidVivo A.3, provides detailed quantitative analysis of arterial plaque composition and stability from CT angiography to aid in atherosclerosis patient stratification and treatment decisions. While both leverage AI for cardiovascular imaging analysis, they address different stages and types of clinical inquiry, making them complementary rather than direct competitors.

Choose iCAC Device if…

Choose the iCAC Device if your primary objective is opportunistic screening for early cardiovascular disease risk in a broad patient population. This tool is ideal for leveraging existing, routine non-contrast chest CT scans to quickly identify and quantify coronary artery calcium, providing adjunctive information for early risk stratification without requiring dedicated cardiac imaging.

View iCAC Device →

Choose ElucidVivo A.3 if…

Choose ElucidVivo A.3 if you require in-depth, quantitative analysis of arterial plaque composition and stability for patients with known or suspected atherosclerosis. This tool is best suited for optimizing treatment decisions and stratifying patient risk by providing detailed visualization and measurement of plaque characteristics from CT angiography, including lipid-rich necrotic core and calcifications, validated against histology.

View ElucidVivo A.3 →

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Quick Comparison

Feature iCAC Device ElucidVivo A.3
Pricing Contact for pricing Unknown
Deployment Software as a Medical Device (SaMD), integrates with PACS or DICOM router. Cloud-based (via Carebricks platform). Cloud and on-premise secure deployment.
FDA Status Cleared AI-estimated Cleared AI-estimated
HIPAA Unknown Yes AI-estimated

Head-to-Head

AI-generated assessment across six dimensions based on each tool's documented features and compliance posture. Grounded in public data — not a substitute for hands-on evaluation.

Usability

iCAC Device

Tool A, iCAC Device, prioritizes seamless integration into existing radiology workflows by leveraging routine, non-contrast, non-gated chest CT scans, eliminating the need for specialized imaging protocols. Its integration with the Carebricks platform further automates patient identification, risk stratification, and care coordination, significantly reducing manual clinician workload and enhancing overall workflow efficiency for opportunistic screening.

Clinical Value

ElucidVivo A.3

Tool B, ElucidVivo A.3, offers superior clinical value through its advanced quantitative analysis of arterial plaque composition and stability, including Lipid-Rich Necrotic Core (LRNC) and derived Fractional Flow Reserve (FFRct), from CT angiography. This detailed characterization is uniquely validated against ground-truth histology, providing deeper, more actionable insights for precise atherosclerosis patient stratification and optimized treatment decisions.

Pricing & Value

iCAC Device

While both tools require direct vendor contact for pricing, Tool A, iCAC Device, has secured a clear reimbursement pathway with CMS establishing a national billing code (G0680) and an associated payment rate of $15.50 for algorithmic analysis of coronary artery calcium (CAC) and aortic valve calcium (AVC). This explicit per-scan reimbursement provides a more immediately quantifiable financial value proposition for health systems implementing opportunistic screening programs.

Enterprise Readiness

iCAC Device

Tool A, iCAC Device, demonstrates stronger enterprise readiness through its explicit classification as Software as a Medical Device (SaMD) and its deployment via the cloud-based Carebricks platform, which is designed for end-to-end care navigation and automation across various clinical and operational workflows. Bunkerhill Health also clearly states compliance with HIPAA, SOC 2, and ISO 27001:2022 standards on its Trust Center, indicating robust security and data governance.

Innovation

ElucidVivo A.3

Tool B, ElucidVivo A.3, exhibits greater innovation by providing a unique, histologically validated quantitative analysis of arterial plaque composition and stability, including LRNC and FFRct, from CT angiography. This capability offers novel predictive insights for personalized atherosclerosis management, effectively delivering 'CT Virtual Histology' and moving beyond traditional diagnostic assistance.

Support & Docs

Tie

Neither the provided structured facts nor the extensive web search results offer sufficient specific information regarding the quality, availability, or scope of support and documentation for either the iCAC Device or ElucidVivo A.3. Therefore, it is not possible to distinguish between the two tools on this dimension.

Feature-by-Feature

Detail beyond the Quick Comparison summary. For pricing, deployment, BAA, FDA, and HIPAA see the Overview tab.

Feature iCAC Device ElucidVivo A.3
Name iCAC Device ElucidVivo A.3
Company Bunkerhill Health Elucid Bioimaging
Primary Purpose Detects and quantifies coronary artery calcium from routine, non-contrast, non-gated chest CT scans, aiding in early cardiovascular disease detection. Provides quantitative analysis of arterial plaque composition and stability from CT angiography, assisting physicians in atherosclerosis patient stratification and optimizing treatment decisions.
Input Scan Type Routine, non-contrast, non-gated chest CT scans CT angiography
Key Output Metrics/Analysis Estimates presence and quantity of coronary artery calcium (CAC), provides visual representation of estimated CAC segmentation, delivers exact and four-category quantitative estimates of CAC burden in Agatston units. AI-powered quantitative analysis of arterial plaque, objectively quantifies Lipid-Rich Necrotic Core (LRNC), matrix, and calcifications, visualizes lesion-level plaque composition, provides 3D visualization of highlighted vessels, offers rotatable curved MPR vessel views and cross-sections, derives fractional flow reserve (FFRct).
Integration Integrates with PACS or DICOM router, integrates with EHRs via the Carebricks platform. Integrates with PACS/EMR (not explicitly detailed).
Specialties Cardiology, Radiology Cardiology, Radiology, Vascular Surgery

Videos

Demos, reviews, and walkthroughs featuring iCAC Device and ElucidVivo A.3.

Loading videos…
Videos need JavaScript to load. Search YouTube directly →

View all on YouTube

Frequently Asked Questions

Bunkerhill Health's iCAC Device analyzes routine, non-contrast, non-gated chest CT scans. ElucidVivo A.3 by Elucid Bioimaging performs quantitative analysis on CT angiography images.
The iCAC Device detects and quantifies coronary artery calcium (CAC) in Agatston units, aiding in early cardiovascular disease detection. ElucidVivo A.3 provides quantitative analysis of arterial plaque composition, including Lipid-Rich Necrotic Core (LRNC), matrix, and calcifications, and derives fractional flow reserve (FFRct).
The iCAC Device supports opportunistic identification of CAC from existing CT scans, assisting in early cardiovascular disease detection. ElucidVivo A.3 aids physicians in atherosclerosis patient stratification and optimizes treatment decisions by offering detailed visualization and measurement of plaque characteristics.
The iCAC Device is designed for Cardiology and Radiology specialties. ElucidVivo A.3 supports Cardiology, Radiology, and Vascular Surgery.
The iCAC Device delivers exact and four-category quantitative estimates of CAC burden in Agatston units. ElucidVivo A.3 objectively quantifies Lipid-Rich Necrotic Core (LRNC), matrix, and calcifications from CT images, and derives fractional flow reserve (FFRct).
The iCAC Device provides adjunctive information to radiologists for early cardiovascular disease detection. ElucidVivo A.3 assists in stratifying patients with atherosclerosis and optimizes treatment decisions by offering detailed visualization and measurement of plaque characteristics validated against histology.
AI Tool Finder
AI-powered search. Results may not be comprehensive.