AngioWaveNet vs Tempus ECG-AF

Similar category, different focus. These tools serve overlapping but distinct needs. Comparability 65/100 Comparability is an AI-graded 0–100 score of how directly these two tools compete — higher means a more apples-to-apples comparison.
by AngioWave
VS
by Tempus AI, Inc.

AI Verdict

AngioWaveNet enhances fluoroscopic angiograms for improved vessel visualization during cardiac catheterization, focusing on procedural support. Tempus ECG-AF, however, analyzes 12-lead ECGs to predict the risk of atrial fibrillation in older patients, serving as a diagnostic risk assessment tool. While both are FDA-cleared AI solutions in cardiology, they address different clinical needs and utilize distinct data types.

Choose AngioWaveNet if…

Choose AngioWaveNet if your primary goal is to enhance the clarity and detail of fluoroscopic angiograms during cardiac catheterization or interventional radiology procedures. This tool is ideal for cath labs and interventional suites seeking to improve real-time vessel visualization and anatomical feature identification, integrating seamlessly with existing angiography systems.

View AngioWaveNet →

Choose Tempus ECG-AF if…

Choose Tempus ECG-AF if your objective is to proactively identify older patients at elevated risk of developing new-onset atrial fibrillation within the next year. This AI-based algorithm is best suited for cardiology, geriatrics, or internal medicine practices looking to leverage routine 12-lead ECGs for early risk stratification and timely follow-up for AF prevention.

View Tempus ECG-AF →

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Quick Comparison

Feature AngioWaveNet Tempus ECG-AF
Pricing Pricing options include annual software licensing or subscription-based access, tailored to cath lab volume and hospital needs. custom packages are available. Contact vendor
Deployment Cloud-based or on-premise/servers Software solution, integrated into healthcare facility systems with advanced cardiology algorithms.
BAA Available Unknown Yes AI-estimated
FDA Status Cleared AI-estimated Yes AI-estimated
HIPAA Yes AI-estimated Yes AI-estimated

Head-to-Head

AI-generated assessment across six dimensions based on each tool's documented features and compliance posture. Grounded in public data — not a substitute for hands-on evaluation.

Usability

AngioWaveNet

AngioWaveNet (Tool A) emphasizes vendor-agnostic compatibility with any fluoroscopic angiography system and functions as a DICOM endpoint, suggesting broad and flexible integration into existing Cath lab workflows. Tempus ECG-AF (Tool B) specifies compatibility with FDA authorized resting 12-lead ECGs from GE Medical Systems and Philips Medical Systems, which might imply a more constrained integration path. AngioWaveNet also states minimal training is required and it can be configured in a few hours.

Clinical Value

AngioWaveNet

AngioWaveNet (Tool A) directly enhances fluoroscopic angiograms for improved vessel visualization, providing immediate and tangible benefits during cardiac catheterization procedures. Tempus ECG-AF (Tool B) offers predictive risk stratification for Atrial Fibrillation, which is valuable for proactive care, but AngioWaveNet's impact on real-time procedural quality is arguably more immediate and critical for interventional success. Both are FDA-cleared and offer significant clinical benefits in their respective domains.

Pricing & Value

Tempus ECG-AF

Tempus ECG-AF (Tool B) provides a clear financial value proposition with explicit CMS reimbursement available (CPT 0764T and CPT 0765T to APC 5734, Medicare rate of $128.90, effective January 1, 2025). While AngioWaveNet (Tool A) offers flexible pricing models like annual licensing or subscription, it lacks specific pricing or reimbursement details, making its financial value less transparent for healthcare providers.

Enterprise Readiness

AngioWaveNet

AngioWaveNet (Tool A) offers both cloud-based and on-premise deployment options and is compatible with any fluoroscopic angiography system, demonstrating high flexibility for diverse enterprise IT environments. While Tempus ECG-AF (Tool B) is HIPAA compliant and provides a BAA, AngioWaveNet's vendor-agnostic approach and deployment versatility give it an edge in adapting to various existing hospital infrastructures.

Innovation

Tempus ECG-AF

Tempus ECG-AF (Tool B) utilizes AI for predictive analytics, identifying patients at increased risk of developing Atrial Fibrillation within 12 months from standard ECGs, which represents a significant advancement in proactive disease management. AngioWaveNet (Tool A) innovates by enhancing existing imaging data for improved visualization during procedures, but predictive risk assessment is generally considered a more transformative application of AI in healthcare.

Support & Docs

Tempus ECG-AF

Tempus ECG-AF (Tool B) explicitly provides contact information for its Cardiology Support team ([email protected] or 800.739.4137) for technical support or inquiries. AngioWaveNet (Tool A) mentions full onboarding support, including installation assistance, staff training, and access to ongoing updates and clinical resources, but does not provide specific contact details for ongoing technical support.

Feature-by-Feature

Detail beyond the Quick Comparison summary. For pricing, deployment, BAA, FDA, and HIPAA see the Overview tab.

Feature AngioWaveNet Tempus ECG-AF
Name AngioWaveNet Tempus ECG-AF
Primary Function Enhances fluoroscopic angiograms for improved vessel visualization in cardiac catheterization laboratories. Analyzes 12-lead ECG recordings to identify patients aged 65 or older at increased risk of developing atrial fibrillation/flutter (AF) within the next 12 months.
Input Modality Fluoroscopic angiograms 12-lead ECG recordings
Target Use Case/Population Improved vessel visualization in cardiac catheterization laboratories. Patients 65 years or older without pre-existing AF, pacemakers, ICDs, or recent cardiac surgery, for identifying increased risk of AF within 12 months.
Vendor Compatibility Compatible with any fluoroscopic angiography system (vendor-agnostic) Compatible with FDA authorized resting 12-lead ECGs from GE Medical Systems and Philips Medical Systems
Core AI Technology AI-powered Spatiotemporal Enhancement Processing (STEPu2122); Post-processing AI for angiographic images. AI-based algorithm for 12-lead ECG analysis, trained on over 1.5 million ECGs.

Videos

Demos, reviews, and walkthroughs featuring AngioWaveNet and Tempus ECG-AF.

Loading videos…
Videos need JavaScript to load. Search YouTube directly →

View all on YouTube

Frequently Asked Questions

AngioWaveNet is FDA-cleared AI software designed to enhance fluoroscopic angiograms, improving vessel visualization in cardiac catheterization laboratories for procedures like angioplasty, stent placement, and cardiac valve interventions. Tempus ECG-AF is an FDA-cleared AI-based algorithm that analyzes 12-lead ECG recordings to identify patients aged 65 or older at increased risk of developing atrial fibrillation/flutter (AF) within the next 12 months.
AngioWaveNet processes fluoroscopic angiographic images to enhance the visibility of blood vessels, vascular structures, and anatomical features, and is compatible with any fluoroscopic angiography system. Tempus ECG-AF analyzes resting 12-lead ECG recordings from patients 65 years or older who do not have a known history of AF, pacemakers, ICDs, or recent cardiac surgery, to detect signs associated with new onset AF within 12 months.
AngioWaveNet integrates with existing Cath lab workflows as a DICOM endpoint for imaging systems, providing enhanced images almost immediately after acquisition. Tempus ECG-AF is a software solution integrated into healthcare facility systems with advanced cardiology algorithms, and its results should be interpreted in conjunction with other diagnostic information and clinical history.
AngioWaveNet is primarily intended for Cardiology, Interventional Radiology, and Vascular Surgery. Tempus ECG-AF is designed to benefit Cardiology, Geriatrics, and Internal Medicine.
AI Tool Finder
AI-powered search. Results may not be comprehensive.