ColonPRO 4.0 (CPRO40S-US)

by Medtronic  · Based in Ireland → — Unlock the potential of AI in endoscopy with the new ColonPRO™ software.
Colorectal Surgery Gastroenterology

Regulatory Status Disclosed

Overview

The ColonPRO™ 4.0 (CPRO40S-US) is an artificial intelligence-based software component of the GI Genius™ intelligent endoscopy module, developed by Cosmo Artificial Intelligence – AI. It is designed to assist endoscopists in real-time detection of colonic mucosal lesions, such as polyps and adenomas, during standard white-light colonoscopy examinations for screening and surveillance. The system analyzes live video images from any compatible endoscope and provides visual markers (e.g., green boxes) on the display to highlight suspicious areas, thereby enhancing lesion detection rates and supporting clinical decision-making. It is not intended to replace the physician’s judgment.

ColonPRO™ 4.0 features improved detection performance through a retrained neural network and introduces a non-clinical “Procedure Highlights” function for data aggregation, supporting healthcare organizations in optimizing their practices.

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Use Cases

  • Real-time assistance during colonoscopy procedures
  • Enhancing detection of colonic polyps and adenomas
  • Improving adenoma detection rates (ADR)
  • Supporting screening programs for colorectal cancer
  • Facilitating surveillance endoscopic mucosal evaluations
  • Data aggregation for practice optimization (via Procedure Highlights)

What Physicians Need to Know

Polyp Detection During Colonoscopy
ColonPRO™ 4.0, part of the GI Genius™ intelligent endoscopy system, is a computer-assisted detection (CADe) device designed to aid endoscopists in detecting colonic mucosal lesions like polyps and adenomas in real-time during standard white-light endoscopy examinations. It uses deep learning algorithms to analyze colonoscopy images and superimpose green boxes on the main endoscopy display when a lesion is detected. The system has a 99.7% sensitivity rate and less than 1% false positives. It helps detect polyps of various sizes, shapes, and morphologies, including flat and non-polypoid ones. Studies show it can reduce the chance of missed polyps by up to 50%.
Real-Time Endoscopy AI
The GI Genius™ system, which includes ColonPRO™ 4.0 software, provides real-time AI assistance during colonoscopies. It offers real-time polyp size estimation and comprehensive procedural highlights. The system processes images in microseconds and displays visual markers to alert physicians to potential colorectal lesions without changing the procedure or withdrawal time.
Adenoma Detection Rate Improvement
The GI Genius™ module has been shown to increase the Adenoma Detection Rate (ADR) by up to 14.4% and reduce adenoma miss rates by approximately 50%. Each 1% increase in ADR is associated with a 3% decrease in the risk of interval cancer. Studies have shown a significant increase in ADR with AI-assisted colonoscopy, including a 12.5% overall increase and a 16.3% increase in the screening population.
Procedure Documentation
ColonPRO™ 4.0 is designed to enhance workflow efficiency and minimize documentation. The quality module (CADq) offers automated measurements of key quality metrics, which can optimize workflow documentation practices.
Quality Metrics Tracking
The quality module (CADq) of ColonPRO™ 4.0 provides automated measurements of key quality metrics. These include inspection times, cecum detection, bowel cleanliness (Boston Bowel Preparation Scale - BBPS), procedure duration, and withdrawal time. While it reliably measures withdrawal time and cecal intubation, AI-based BBPS scoring requires further validation.
Endoscopy System Compatibility
The GI Genius™ intelligent endoscopy module, which incorporates ColonPRO™ 4.0, is designed for seamless integration and universal compatibility. It connects to existing endoscopy towers, high-definition endoscopes, video processors (including Olympus, Fujifilm, and Pentax brands), and display monitors. The system is compatible with video processors featuring SDI, HD-SDI, 3G/SDI, and 4K UHD (12G-SDI) output ports, and endoscopic display monitors with corresponding input ports.
Physician Tip

ColonPRO™ 4.0 acts as an ever-vigilant second observer, enhancing polyp detection during colonoscopy without altering your standard procedure or withdrawal time. Utilize the real-time polyp sizing module for accurate measurements to guide post-polypectomy surveillance intervals. Leverage the quality module for automated tracking of key metrics like inspection times and cecum detection to optimize your practice. While the system aids in detection, it is not intended to replace clinical decision-making or characterize lesions in a manner that would replace biopsy sampling.

The GI Genius™ system, powered by NVIDIA Holoscan and IGX Orin, is designed as a cohesive platform to support a variety of future real-time AI applications through a single platform. It is positioned for future electronic health record integration and supports third-party application development.

Details

Category Gastroenterology AI
Pricing Unknown
DeploymentOn-premise, integrated with the GI Genius™ intelligent endoscopy module hardware.
Compliance
BAA AvailableUnknown
HIPAA CompliantUnknown
FDA Status Cleared AI-estimated

ColonPRO™ 4.0 (CPRO40S-US) received FDA clearance. The GI Genius™ intelligent endoscopy module, which ColonPRO™ software runs on, received De Novo FDA clearance in 2021 as the first and only commercially available computer-aided detection (CADe) system using AI to identify colorectal polyps. It is a computer-assisted reading tool designed to aid endoscopists in detecting colonic mucosal lesions (such as polyps and adenomas) in real time during standard white-light endoscopy examinations of patients undergoing screening and surveillance endoscopic mucosal evaluations. The device is limited for use with standard white-light endoscopy imaging only and is not intended to replace clinical decision making. ColonPRO™ 4.0 has also been identified as the first FDA-approved computer-aided quality (CAQ) platform for use in colonoscopy.

GDPR Yes AI-estimated
Integrations
EHR Not specified
Specialties Colorectal Surgery, Gastroenterology

Support & Reliability

FDA clearance history

This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.

Decision dateNumberName as listed by FDA
2024-07-25K241887 510(k)ColonPRO™ 4.0 (CPRO40S-US)

What the Web Says

Medtronic's ColonPRO™ 4.0 (CPRO40S-US) is the latest generation AI-assisted software for colonoscopy, designed to enhance polyp detection and improve procedural quality. It has received CE Mark approval and FDA clearance, and studies indicate it significantly reduces adenoma and polyp miss rates compared to standard colonoscopies. The system also offers real-time polyp size estimation and comprehensive procedural highlights to optimize colonoscopy practice.

Overall: Positive

Strengths

  • Significantly decreases the miss rate of colorectal polyps and adenomas.
  • Increases adenoma detection rates (ADR) by up to 14.4%.
  • Reduces adenoma miss rates by approximately 50%.
  • Provides real-time polyp size estimation.
  • Offers comprehensive procedural highlights, automating workflow and reducing administrative burden.
  • High sensitivity rate (99.7%) and low false positives (less than 1%).

Limitations

  • One physician reviewer noted that the economic value of an earlier version of the CAQ program seemed to be zero, as some features like total procedure and withdrawal times are already easily obtainable.
  • The same reviewer found the CAQ program's rating of Boston Bowel Preparation Scale (BBPS) scores to be inaccurate, potentially altering recall recommendations in a significant percentage of cases.
  • The earlier version of the program did not provide real-time feedback on mucosal exposure, withdrawal speed, or actual inspection time, which were identified as valuable potential features.
  • General Medtronic customer service and product reliability (for other products) have received negative feedback on Trustpilot.

Based on reviews from: lww.com, medtronic.com, scilit.com, cnet.com, biopharmawatch.com, massdevice.com, asge.org, medicaldesignandoutsourcing.com, youtube.com, trustpilot.com, surgicalroboticstechnology.com, reddit.com, medicaldesigndevelopment.com, reachmd.com

Last updated: 2026-10-29

Ratings & Reviews

No reviews yet. Be the first to review this tool!

Rate ColonPRO 4.0 (CPRO40S-US)

Clinical Value
Ease of Use
Integration
Support & Docs
Value for Money

Press & Coverage

PRNewswire
Medtronic unveils the future of AI in GI: Genius Summit 2024 reveals innovations and collaborations that advance endoscopic care
Medtronic announced the launch of ColonPRO™, the latest generation software for its GI Genius™ intelligent endoscopy system, which features an enhanced AI algorithm for improved polyp detection with a 9% reduction in false positives and new procedural highlights for workflow automation. The company also revealed a strategic collaboration with Modernizing Medicine® to enhance patient care.
2024-04
Medtronic.com
Medtronic receives CE Mark for ColonPRO™ 4th generation software for AI-assisted colonoscopy
Medtronic announced it has received CE Mark approval for ColonPRO™, the 4th generation software for AI-assisted colonoscopy, which uses deep learning algorithms to support endoscopists with real-time polyp size estimation and comprehensive procedural highlights. The software is designed to optimize colonoscopy practice and integrates with the GI Genius™ platform.
2026-02
MassDevice
Medtronic receives CE Mark for ColonPRO fourth-generation software for AI-assisted colonoscopy
Medtronic announced it received CE Mark for its ColonPRO fourth-generation software for AI-assisted colonoscopy, which utilizes deep learning algorithms to support endoscopists in optimizing colonoscopy practice by offering real-time polyp size estimation and comprehensive procedural highlights. This new software bolsters Medtronic's GI Genius platform, which was introduced in 2019.
2026-02
National Institutes of Health (NIH)
Prospective Validation of the First US FDA-Approved Computer-Aided Quality Assessment Tool for Colonoscopy: An Initial Clinical Experience
A prospective pilot study of GI Genius ColonPro 4.0 (Medtronic, Minneapolis, MN), the first US FDA-approved computer-aided quality (CAQ) platform for colonoscopy, found strong agreement between CAQ and physicians for withdrawal time and cecal intubation, but poor agreement for Boston Bowel Preparation Score (BBPS).
2026-04
American Society for Gastrointestinal Endoscopy (ASGE)
GI Genius ColonPro 4.0 receives FDA approval for use in colonoscopy
A recent study identified the GI Genius ColonPro 4.0 (Medtronic, Minneapolis, MN) as the first computer-aided quality (CAQ) platform to receive Food and Drug Administration (FDA) approval for use in colonoscopy. The study showed strong agreement between the CAQ program and manual measurements for total procedure time, withdrawal time, and cecal identification.
2025-11
ReachMD
FDA 510(k) Clearances - May 21, 2026
The FDA 510(k) clearances for May 21, 2026, include ColonPRO™ 4.0 (CPRO40S-US) from Cosmo Artificial Intelligence - Ai, Ltd. GI Genius and ColonPRO are AI systems that analyze video during live colonoscopy to help gastroenterologists detect polyps and lesions in real time.
2026-05

Videos

Product demos, reviews, and walkthroughs for ColonPRO 4.0 (CPRO40S-US).

Loading videos...

View all on YouTube

Frequently Asked Questions

ColonPRO™ 4.0 (CPRO40S-US) is the fourth-generation AI-assisted colonoscopy software developed by Medtronic, designed to optimize colonoscopy practice. It leverages deep learning algorithms to provide real-time polyp size estimation and comprehensive procedural highlights, enhancing polyp detection and characterization during colonoscopies.
ColonPRO™ 4.0, as part of the GI Genius™ system, has been shown to increase adenoma detection rates by up to 14.4% and reduce adenoma miss rates by approximately 50% compared to standard colonoscopy. It also offers a quality module (CADq) that provides automated measurements of key quality metrics such as inspection times, cecum detection, and bowel cleanliness.
While ColonPRO™ 4.0 reliably measures withdrawal time and cecal intubation, its agreement with physicians for Boston Bowel Preparation Scale (BBPS) scores has been poor in studies, potentially altering recall recommendations. The device is intended to aid endoscopists and not to replace clinical decision-making, and it has not been studied in patients with Inflammatory Bowel Disease, a history of Colorectal Cancer, or previous colonic resection.
ColonPRO™ 4.0 is part of the GI Genius™ system, which received FDA clearance in 2021. It is classified as a Class II medical device under 21 CFR 876.1520, meaning it must comply with FDA regulations including registration, labeling, medical device reporting, and good manufacturing practices. Specific details on data privacy compliance beyond general medical device regulations are not readily available.
Yes, other companies offer AI-based endoscopy units and real-time polyp detection systems. These include Olympus Corporation's ENDO-AID CADe, PENTAX Medical's DISCOVERY AI, and Iterative Health's SKOUT polyp detection platform.
Information regarding the specific pricing or acquisition model for ColonPRO™ 4.0 (CPRO40S-US) is not publicly available in the provided search results. For pricing details, it would be best to contact Medtronic directly.

Related Tools

GHAPP
GHAPP
Gastroenterology AI
GHAPP is a digital learning hub dedicated to providing educational programs and resources for Advanced Practice Providers (APPs) in gastroenterology and hepatology.
Deep Capsule® (Deep Capsule US)
Digestaid - Artificial Intelligence Development SA
Clinical Decision Support & Reference
Deep Capsule® is an AI-powered tool by Digestaid for analyzing capsule endoscopy videos, designed to enhance the detection and differentiation of small bowel lesions and reduce review time for clinicians.
ColonPRO 4.0 (CPRO40.US)
Cosmo Artificial Intelligence - AI
Gastroenterology AI
Cosmo Artificial Intelligence - AI is a life sciences company focused on MedTech AI, dermatology, and gastroenterology, developing innovative products and partnering globally to empower patients and healthcare professionals through technology.
ColonPRO US
Cosmo Artificial Intelligence - Ai, Ltd.
Clinical Decision Support & Reference
ColonPRO™ US is an AI-powered device that assists gastroenterologists in real-time polyp detection and characterization during colonoscopy.
Instrument Exit Point on Touch Surgery Aide
Covidien, LLC
Gastroenterology AI
Instrument Exit Point on Touch Surgery™ Aide is an AI-powered surgical guidance tool for precise instrument placement in gastrointestinal and urological procedures.
G-EYE Colonoscope
SMART Medical Systems
Gastroenterology AI
The G-EYE® Colonoscope is a medical device developed by SMART Medical Systems, specializing in gastroenterology and gastrointestinal endoscopy. It is designed to assist in colonoscopy procedures. This device is intended for use by gastroenterologists and other medical professionals performing colonoscopies in clinical settings. It integrates into the existing clinical workflow of colonoscopy. Notable capabilities of […]

See all Gastroenterology AI tools →

More from Cosmo Artificial Intelligence – AI

ColonPRO 4.0 (CPRO40.US)
Cosmo Artificial Intelligence - AI
Gastroenterology AI
Cosmo Artificial Intelligence - AI is a life sciences company focused on MedTech AI, dermatology, and gastroenterology, developing innovative products and partnering globally to empower patients and healthcare professionals through technology.
ColonPRO US
Cosmo Artificial Intelligence - Ai, Ltd.
Clinical Decision Support & Reference
ColonPRO™ US is an AI-powered device that assists gastroenterologists in real-time polyp detection and characterization during colonoscopy.
GI Genius
Medtronic
Gastroenterology AI
GI Genius Module 100
Medtronic
Gastroenterology AI
The GI Genius™ Module 100 is an FDA-cleared, AI-powered computer-aided detection system that assists physicians in real-time detection of colonic polyps and adenomas during colonoscopy, enhancing visualization and improving detection rates.

View company profile →

Suggest an Edit → | Report an issue | Last Verified: 2026-11-05 | First Added: 2026-04-18
AI Tool Finder
AI-powered search. Results may not be comprehensive.