Overview

CT VScore+ by Canon Medical Informatics is an advanced software application designed for the non-invasive evaluation of calcified lesions in the coronary arteries. Running on the robust Vitrea platform, this AI-powered tool automates cardiac calcium scoring, significantly reducing the need for manual data entry in the reporting process. It precisely generates Agatston and volume calcium scores for key coronary arteries (combined LM+LAD, RCA, LCX) based on the volume and density of calcium deposits. The system visually highlights segmented calcium directly on the original CT images and offers the option to display these scores in the context of established reference data from the MESA and Hoff-Kondos databases, aiding in comprehensive cardiac risk assessment. CT VScore+ supports both 2D and 3D visualization and includes report templates that auto-fill user-selected scores, complete with snapshots and graphs for streamlined clinical reporting and improved workflow efficiency.

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Key Features

  • Automated cardiac calcium scoring
  • Removes manual data entry from reporting
  • Generates Agatston and volume calcium scores
  • Highlights segmented calcium on CT images
  • Runs on Vitrea platform
  • Non-invasive evaluation of coronary artery calcified lesions
  • Utilizes ECG-gated, non-contrast cardiac CT images
  • Provides calcium percentile comparison to reference data (MESA, Hoff-Kondos)
  • 2D and 3D visualization
  • Report template autofills user-selected scores with snapshots and graphs

Use Cases

  • Coronary artery calcium (CAC) scoring
  • Non-invasive evaluation of calcified lesions
  • Cardiac risk assessment
  • Streamlining reporting workflows for cardiac CT
  • Supporting in-house 3D imaging services
  • Assessing cardiovascular disease risk in asymptomatic individuals

What Physicians Need to Know

ECG/EKG Analysis Capability
Utilizes ECG-gated, non-contrast cardiac CT images for acquisition, which is crucial for minimizing motion artifacts and ensuring accurate coronary calcification assessment.
Cardiac CT/MRI Analysis
Specifically designed for cardiac CT analysis, providing 2D and 3D visualization of coronary calcification. It automatically generates Agatston and volume calcium scores from non-contrast cardiac CT exams and highlights segmented calcium on the original CT image.
Heart Failure Risk Prediction
Enables clinical reporting for coronary risk assessment by calculating coronary artery calcium (CAC) scores. These scores are a key indicator for predicting the likelihood of future cardiovascular events, including heart attacks, and contribute to overall cardiovascular risk stratification.
Coronary Artery Assessment
Provides comprehensive assessment of coronary artery calcification, including visualization, measurement, and reporting. It calculates calcium scores using Agatston, Volume, or Mass methods and displays the calcium percentile relative to age, gender, and ethnic reference populations. It focuses on non-invasive evaluation of calcified lesions in specific coronary arteries (LM+LAD, RCA, LCX).
Cardiac Monitoring Integration
Integrates with ECG signals during CT image acquisition to ensure proper cardiac gating, which is essential for obtaining high-quality, motion-free images necessary for accurate calcium scoring.
AHA/ACC Guideline Alignment
The tool's output, coronary artery calcium scores, aligns with AHA/ACC guidelines for cardiovascular risk assessment, particularly for reclassifying atherosclerotic cardiovascular disease risk in asymptomatic individuals. It offers the option to display scores in the context of reference data from databases like MESA and Hoff-Kondos.
Physician Tip

CT VScore+ is a valuable tool for efficiently and accurately quantifying coronary artery calcification, a critical biomarker for cardiovascular risk. Physicians can leverage the Agatston, Volume, or Mass scores, along with percentile comparisons to reference populations, to enhance personalized risk stratification. This information is instrumental in guiding decisions regarding preventive interventions, such as statin therapy or lifestyle modifications, and can be integrated into broader cardiovascular risk prediction models to inform patient management strategies. The non-invasive nature of the calcium scoring exam, facilitated by this tool, allows for early detection and proactive management of coronary artery disease.

CT VScore+ is a software application that operates on the Vitrea Advanced Visualization platform by Canon Medical Systems. It is designed to process ECG-gated, non-contrast cardiac CT images, indicating seamless integration with CT scanners capable of ECG synchronization and the Vitrea advanced visualization system for post-processing and reporting.

Details

Category Cardiology AI, Radiology & Imaging AI
Pricing Contact for pricing
DeploymentOn-premise
Compliance
BAA AvailableUnknown AI-estimated
HIPAA CompliantUnknown AI-estimated
FDA Status 1 AI-estimated

CT VScore+ is a software application intended for non-invasive evaluation of calcified lesions of the coronary arteries based on ECG-gated, non-contrast cardiac CT images for patients aged 30 years or older. The device automatically generates Agatston and volume calcium scores for each of the coronary arteries and highlights the segmented calcium on the original CT image. It also offers the option to display scores in the context of MESA and Hoff-Kondos databases.

Integrations
EHR Not specified
Specialties Cardiology, Radiology

What the Web Says

CT VScore+ is an automated coronary calcium scoring solution that aims to improve workflow efficiency and streamline the calcium scoring process within the Vitrea Advanced Visualization platform. It is designed to reduce manual effort while maintaining clinical oversight and has shown significant improvements in processing time, particularly with more complex cases.

Overall: Positive

Strengths

  • Automated calcium scoring reduces manual effort.
  • Improved workflow efficiency (2.3x improvement in a 100-case study).
  • Streamlined review-first workflow for physicians and technologists.
  • Demonstrates strong clinical reliability and expert-level accuracy.
  • Identifies subtle coronary calcium findings that manual scoring might miss.
  • Performance gains increase with case complexity.

Limitations

  • Specific pricing information is not readily available.
  • No user ratings or detailed reviews found on G2 or Capterra.
  • Limited independent tech reviews available.
  • Some Reddit discussions about CT calcium scoring in general mention insurance often not covering the cost, though this is not specific to CT VScore+.
  • One Reddit comment expressed a negative opinion about Canon CT scanners in general, citing frequent hardware/software failures and poor image quality, which could be relevant as CT VScore+ is from Canon Medical Informatics.

Based on reviews from: Canon Medical Informatics, Physician AI Tools, Reddit

Last updated: 2026-07-17

Ratings & Reviews

No reviews yet. Be the first to review this tool!

Rate CT VScore+

Clinical Value
Ease of Use
Integration
Support & Docs
Value for Money

Press & Coverage

FDA
CT VScore+ 510(k) Clearance
Canon Medical Informatics, Inc. received FDA 510(k) clearance for CT VScore+ on November 28, 2025. This software application is intended for non-invasive evaluation of calcified lesions of the coronary arteries using ECG-gated, non-contrast cardiac CT images for patients aged 30 years or older.
2025-11
Innolitics
2025 Year in Review: Cardiology AI/ML SaMD 510(k) Clearances
This article provides a comprehensive analysis of 2025 cardiology AI/ML clearances, including CT VScore+ by Canon Medical Informatics, Inc., which was cleared on November 28, 2025, as a CAC-related device.
2026-01
Canon Medical Informatics
Scaling Cardiac CT Workflow Through Automation
South Tampa Cardiology partnered with Canon Medical Informatics to evaluate CT VScore+ and achieved a 2.3x improvement in workflow efficiency and streamlined calcium scoring in a 100-case real-world study.
unknown
Canon Medical Informatics, Inc.
TRANSFORMING CORONARY CALCIUM SCORING WORKFLOW WITH CT VSCORE+
A case study details how CT VScore+, part of the Vitreau00ae Advanced Visualization platform, automated coronary calcium scoring at South Tampa Cardiology, leading to a 2.3x improvement in workflow efficiency and a 57% reduction in processing time.
unknown
accessdata.fda.gov
Establishment Registration & Device Listing - CT VScore+
This FDA listing confirms CT VScore+ (Product Code: JAK) as a Class 2 medical device under regulation number 892.1750, classified as a Computed Tomography X-Ray System.
2026-04
MedSource | MedIndexer
Top vendors for Imaging AI, compared u2014 MedSource | MedIndexer
Canon Medical Informatics' CT VScore+ module is highlighted for automating cardiac calcium scoring at health-system scale across CT and cardiac CT.
2026-04
MedIndexer
Endoscopy & Visualization vendors in the US - MedIndexer
Canon Medical Informatics' Vitreau00ae Advanced Visualization platform includes CT VScore+ for automated cardiac calcium scoring, designed to streamline radiologist workflows and reduce manual data entry.
unknown
FDA
TPLC - Total Product Life Cycle - FDA
The FDA's Total Product Life Cycle database lists CT VScore+ (K252217) as a cleared device from Canon Medical Systems Corporation, categorized under Computed Tomography X-Ray System.
2026-07

Videos

Product demos, reviews, and walkthroughs for CT VScore+.

View all on YouTube

Frequently Asked Questions

CT VScore+ is a software application designed to automate cardiac calcium scoring from ECG-gated, non-contrast cardiac CT images. It integrates into existing workflows by automatically generating Agatston and volume calcium scores for coronary arteries, highlighting segmented calcium, and can be exported for clinical reporting and risk assessment.
CT VScore+ has undergone performance testing to validate analytical accuracy and demonstrate substantial equivalence to a predicate device, following FDA-recognized statistical methods. While specific details on CE Mark or explicit HIPAA/GDPR compliance mechanisms for CT VScore+ itself aren't detailed in the provided information, AI tools in healthcare generally face significant safety, privacy, reliability, and ethical considerations, requiring rigorous oversight and validation processes to ensure compliance and guard against legal repercussions.
Yes, there are other AI tools for coronary artery calcium (CAC) scoring, with some vendors offering automation in this area. CT VScore+ differentiates itself by automating cardiac calcium scoring and removing manual data entry from the reporting process, running on the Vitrea platform, and offering the option to display scores in the context of reference databases like MESA and Hoff-Kondos.
The provided search results do not contain specific information regarding the pricing model, tiers, or subscription options for CT VScore+. Physicians would typically inquire directly with Canon Medical Informatics or their sales representatives for such details.
CT VScore+ is intended for patients aged 30 years or older. While performance testing was conducted to validate analytical accuracy, specific details on potential biases or comprehensive accuracy metrics beyond 'high accuracy' for similar AI-CAC tools are not explicitly detailed for CT VScore+ in the provided information. General AI limitations in healthcare include potential biases if training data is incomplete or skewed, leading to inequitable outcomes.
CT VScore+ is a diagnostic support tool that automatically generates calcium scores and highlights findings, intended to assist in the non-invasive evaluation of coronary artery calcification. AI in medicine is generally seen as a tool to augment, rather than replace, human intelligence, empowering physicians to enhance clinical care. Physicians will continue to play a critical role in ensuring ethical and moral implications are considered and that patients receive the highest quality of care.
The provided information does not specifically detail how CT VScore+ handles unexpected or ambiguous findings, nor does it outline a process for reporting and addressing potential errors. However, the integration of AI tools in clinical practice requires careful validation, training, and ongoing monitoring to ensure accuracy, safety, and effectiveness. Physicians are concerned about the reliability and transparency of AI systems, including the ability to understand and explain AI decisions.

Related Tools

EchoMD AutoEF
Caption Health (formerly Bay Labs, now part of GE HealthCare)
Cardiology AI
EchoMD AutoEF is an FDA-cleared AI software that automates the selection of echocardiogram clips and calculates left ventricular ejection fraction (EF), enhancing efficiency and accuracy in cardiac assessments.
ECG-AI Cardiac Amyloidosis (CA) 12-Lead Algorithm
Anumana, Inc.
Cardiology AI
An AI algorithm for screening cardiac amyloidosis using standard 12-lead ECGs.
DEEPVESSEL Plaque
Keya Medical Technology Co., Ltd.
Cardiology AI
An AI software platform for coronary plaque analysis and quantification from CT angiography.
WatchMate Software
Anumana, Inc.
Cardiology AI
Anumana is an AI-driven health technology company from nference, developing and delivering ECG algorithms enabling early diagnosis and intervention.
syngo.CT Coronary Cockpit
Siemens Healthineers
Cardiology AI
syngo.CT Coronary Cockpit is an AI-powered software tool by Siemens Healthineers for efficient and accurate CT coronary angiography analysis.
HeartLung AI-CVD®
HeartLung Corporation
Cardiology AI
HeartLung AI-CVD® is an FDA-cleared AI-powered quantitative imaging tool that provides automated CT-derived measurements for assessing cardiovascular and multisystem risks opportunistically.

See all Cardiology AI tools →

Suggest an Edit → | Last Verified: 2026-04-17 | First Added: 2026-04-17