Sense System with IBT Electrodes
Overview
The Sense System with IBT Electrodes is a surface electromyography (EMG) electrode system developed by Infinite Biomedical Technologies (IBT) to enhance the control of upper limb prosthetic devices. This system utilizes a sophisticated pattern recognition algorithm to interpret muscle signals, translating them into intuitive commands for prosthetic hands, wrists, and elbows. The IBT Electrodes, previously cleared by the FDA, detect the EMG signals, which are then processed by the Sense System’s control box.
Designed with user comfort and adaptability in mind, the Sense System features some of the smallest control box and electrodes available on the market, along with lower battery consumption for extended use. It includes user interface software that allows prosthetists and patients to view signals, calibrate, and adjust device settings. A unique feature is its single movement recalibration, saving time and effort for users. The system also integrates with a virtual training app, MyoTrain, and offers a mobile app for on-the-go calibration, making it more natural and adaptable to individual muscle contractions and changes in limb volume or fit. IBT’s mission is to improve the lives of individuals with limb loss through the development of meaningful devices, and the Sense System is a key part of their advanced technologies for upper-limb amputees.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- Surface Electromyography (EMG) electrode system
- AI-powered pattern recognition algorithm for prosthetic control
- Enhances control of upper limb prosthetic devices
- Detects EMG signals using IBT Electrodes
- Compatible with various prosthetic hands, wrists, and elbows
- Smallest control box and electrodes on the market
- Lower battery consumption for extended use
- User Interface Software for calibration and settings adjustment
- Single movement recalibration feature
- Virtual training app (MyoTrain) included
- Mobile app for on-the-go calibration
- Intuitive control based on phantom limb sensations
- Adaptable to changes in fit, skin fatigue, or limb volume
Use Cases
- Intuitive control of upper limb prostheses
- Rehabilitation for individuals with upper limb loss
- Pre-prosthetic training using virtual environments
- Improving quality of life for amputees
- Advancing prosthetic technology research and development
What Physicians Need to Know
For clinicians working with the Sense System with IBT Electrodes for prosthetic control, focus on leveraging its pattern recognition capabilities to provide intuitive and adaptable control for upper limb prostheses. Utilize the system's software and mobile app for precise calibration and to accommodate changes in limb volume or muscle fatigue, ensuring optimal patient comfort and functionality. Encourage patients to use the mobile app for on-the-go adjustments to enhance their daily independence.
The Sense System with IBT Electrodes is designed to be compatible with an array of connected upper limb prosthetic devices, such as hands, wrists, or elbows. Its pattern recognition algorithm processes EMG signals to provide standardized output signals for these prostheses. The system also integrates with a mobile application for user-driven adjustments and recalibration. Virtual game-based training tools, like MyoTrain, can be used to help patients learn pattern recognition prior to receiving their prosthesis, providing a fun and realistic training environment.
Details
| Category | Neurology AI, Wearables & Remote Monitoring (RPM) |
| Pricing | Contact for pricing |
| Deployment | Device-based (integrated into prosthesis) with accompanying desktop software and mobile application. |
| Compliance | |
| BAA Available | Unknown AI-estimated |
| HIPAA Compliant | Unknown AI-estimated |
| FDA Status |
1 AI-estimated The Sense System with IBT Electrodes received FDA 510(k) clearance (K182112) on October 5, 2018. It is indicated for use exclusively for external prosthetic fittings of upper limbs, enhancing control of prosthetic devices through surface electromyography (EMG) and pattern recognition. |
| Integrations | |
| EHR | Not specified |
| Specialties | Orthopedics, Physical Medicine & Rehab, Plastic Surgery |
What the Web Says
The Sense System with IBT Electrodes is a surface electromyography (EMG) electrode system designed to enhance the control of upper limb prosthetic devices. It utilizes pattern recognition algorithms to interpret muscle signals and translate them into prosthetic movements, offering a more intuitive control for users. The system includes a control box and up to eight small, low-profile electrodes, aiming to minimize the fabrication footprint and reduce battery consumption. It is intended for prescription use and installed by prosthetists or trained clinicians.
Overall: MixedStrengths
- Enhances control of upper limb prosthetics through intuitive pattern recognition.
- Smallest control box and electrodes on the market, minimizing bulk.
- Lower battery consumption for extended use.
- Software allows for single movement recalibration, saving time and effort for patients.
- Accommodates non-traditional myo patients with weaker signals due to multiple electrodes.
- Includes a virtual training app (MyoTrain) for practice before receiving the prosthesis.
Limitations
- Limited publicly available reviews from physicians, healthcare IT, or tech reviewers outside of promotional materials.
- No specific reviews found on G2 or Capterra.
- Reddit discussions primarily focus on the iBioMed academic program at McMaster University, not the product itself.
- General Reddit discussions about electrodes or similar technologies sometimes mention issues like discomfort, difficulty in application, or limited effectiveness for pain relief (not directly related to prosthetic control).
Based on reviews from: AccessGUDID - NIH, accessdata.fda.gov, YouTube (Infinite Biomedical Technologies channel), Reddit (r/McMaster, r/ChronicPain, r/flexibility, r/CPTSDNextSteps, r/answers), FDA (510(k) Premarket Notification), McMaster's Faculty of Engineering, Quora, Root3 Labs, Tom's Guide, PMC (Medical Devices for Tremor Suppression: Current Status and Future Directions, Patient-Reported Satisfaction with Using a Rechargeable 10 kHz Spinal Cord Stimulation Device), Northwell Health, Cybernews, Trustpilot
Last updated: 2026-07-19
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate Sense System with IBT Electrodes
Press & Coverage
Videos
Product demos, reviews, and walkthroughs for Sense System with IBT Electrodes.
No videos found. Search YouTube directly