VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
Overview
The VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464) is a state-of-the-art nuclear imaging solution from Spectrum Dynamics Medical. This system features a 360-degree ring-shaped gantry with 12 swiveling Cadmium Zinc Telluride (CZT) detectors that automatically adjust to the patient’s body contour for personalized exams and enhanced sensitivity. It integrates a digital SPECT scanner with a 16-slice or 64-slice premium CT scanner, allowing for independent use of each component. The VERITON-CT 400 Series is designed for a wide range of applications, including theranostics, nuclear cardiology, general nuclear medicine, oncology, and neurology. It supports imaging across a broad spectrum of radioisotopes, from low to high energy, including Technetium-99m, Iodine-123, Lutetium-177, Iodine-131, and Actinium-225, often without the need for collimator exchange. The system emphasizes high sensitivity, resolution, and quantitative accuracy, with features like attenuation correction, scatter correction, and partial volume correction to support SUV calculations and dosimetry. An “All-Energy Enhancement” further expands its capabilities for comprehensive theranostics imaging.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- 360-degree digital CZT SPECT/CT platform
- 12 swiveling CZT detectors for personalized body contouring
- Integrated 16-slice or 64-slice premium CT scanner
- All-Energy Enhancement for broad radioisotope imaging (40-400+ keV)
- High sensitivity and resolution
- Quantitative imaging with attenuation, scatter, and partial volume correction
- 80cm wide bore for patient comfort and accommodation
- Total body imaging up to 200cm
- AI-enhanced imaging with Veritas.AI Noise Reduction
- Designed for theranostics, nuclear cardiology, and general nuclear medicine
Use Cases
- Theranostics imaging and therapy guidance
- Nuclear cardiology studies, including myocardial perfusion imaging and flow reserve quantification
- Oncology for lesion detection, staging, and treatment response assessment
- Neurological disorder evaluation
- General nuclear medicine applications
- Quantitative imaging for dosimetry and tumor burden calculations
Details
| Category | Oncology AI, Radiology & Imaging AI |
| Pricing | Unknown |
| Deployment | On-premise (medical device) |
| Compliance | |
| BAA Available | Unknown |
| HIPAA Compliant | Unknown |
| FDA Status | Cleared AI-estimated |
| Integrations | |
| EHR | Not specified |
| Specialties | Nuclear Medicine, Oncology, Radiology |
FDA clearance history
This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.
| Decision date | Number | Name as listed by FDA |
| 2026-01-13 | K254001 510(k) | VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464) |