(Elements) Dose Review

by Brainlab AG  · Based in Germany → — Innovating Medtech for Better Patient Outcomes
Oncology

Contact for pricing
Regulatory Status Disclosed

Overview

Brainlab Elements Dose Review is a software application within the comprehensive Brainlab Elements suite, designed for advanced radiation therapy planning and review. The Elements suite provides immediate access to a range of pre-planning software applications that work seamlessly together, bridging various clinical subspecialties such as radiation oncology, neurosurgery, and spine surgery. Elements Dose Review specifically enables thorough analysis of dose distribution to target volumes and critical structures, offering features like zoom-adaptive dose display, dose-volume histograms for detailed plan review, and the ability to compare different plan alternatives. This helps clinicians illuminate options and gain reassurance prior to treatment delivery. The broader Elements platform also includes AI-powered segmentation for various anatomical regions, including cranial, basal ganglia, head & neck, pelvic, spine, and extracranial areas, as well as tools for image fusion and trajectory planning, all aimed at streamlining workflows and enhancing precision in treatment planning.

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Key Features

  • Thorough dose-to-target and dose-to-critical-structures models
  • Plan comparison and review
  • Zoom-adaptive dose display
  • Dose-volume histograms for detailed plan review
  • Comparison of plan alternatives
  • AI-powered tumor segmentation (within Elements Retreatment Review)
  • Image fusion and co-registration
  • Patient anatomy segmentation
  • Modular software applications
  • Multi-platform flexibility (workstation, mobile devices)

Use Cases

  • Radiation treatment planning
  • Stereotactic Radiosurgery (SRS) planning
  • Surgical planning (e.g., neurosurgery, spine surgery)
  • Retreatment analysis and planning for recurring lesions
  • Pre-planning for cranial and extracranial surgical and radiotherapy treatments
  • Functional neurosurgery planning (e.g., DBS, sEEG, biopsies)

What Physicians Need to Know

Key Capabilities
Elements Dose Review offers features for reviewing isodose lines, Dose-Volume Histograms (DVHs), and enabling dose comparison and summation. It facilitates thorough dose-to-target and dose-to-critical-structures models, as well as the comparison of plan alternatives. The software supports 3D visualization of previously treated and new metastases for retreatment analysis and allows for review options for the summed dose of previous treatment plans. It also includes tools for patient-specific quality assurance (QA) by recalculating patient treatment plans on a phantom to verify planning requirements. The software can define and edit Hounsfield to electron density conversion tables. It also features zoom-adaptive dose display. The software is designed to streamline pre-planning workflows, transforming image preprocessing into actionable treatment plans through intuitive modules for automation, contouring, merging, and viewing. It also offers advanced 3D visualization for enhanced spatial anatomical orientation.
Clinical Utility
Elements Dose Review is intended for radiation treatment planning in stereotactic, conformal, computer-planned, Linac-based radiation treatment for cranial, head and neck, and extracranial lesions. It helps clinicians analyze and compare dose distributions to ensure optimal target coverage while minimizing exposure to organs at risk. The tool is particularly useful for re-irradiation cases in brain metastases, allowing for cumulative dose assessment across different planning systems and treatment courses to avoid hotspots and reduce the risk of radiation necrosis. It supports efficient and accurate treatment planning, potentially reducing treatment durations and enhancing overall outcomes. The software can also be used to verify patient treatment plans against planning requirements.
Integration Options
Brainlab Elements, including Dose Review, is designed for seamless integration with other Brainlab platforms such as Curve™ Image Guided Surgery and Buzz® Digital O.R. It supports collaboration across departments and locations, with compatibility for mobile devices and workstations. The system can import prior RT-DOSE information from other planning systems like GammaPlan for cumulative dose assessment. It processes co-registered DICOM image sets as input and outputs DICOM RT dose plans for further processing and controlling radiation delivery to a patient using a linear accelerator. The Anatomical Patient Model (APM) component of RT Elements includes a gRPC API, serving as an algorithmic backend for medical image data processing.
Compliance Status
Brainlab Elements Dose Review is FDA 510(k) cleared and classified as a Class II medical device under regulation number 21 CFR 892.5050 (Medical Charged-Particle Radiation Therapy System). It is also CE marked. All medical devices, including Class I and unclassified devices, and combination product device constituent parts, are required to comply with the Unique Device Identification System (UDI) Rule.
Pricing Model
Brainlab provides flexible business models, offering scalable options from simple, single licenses to multiple offerings across various departments.
User Experience
The software is designed to be user-friendly and intuitive, controllable via mouse and keyboard, and displayed on a computer screen. It offers multi-platform flexibility, allowing users to work online on preferred devices, including iPad and iPhone, or offline on a workstation. This flexibility aims to accommodate busy clinicians and various departmental IT setups. The software streamlines pre-planning workflows, transforming image preprocessing into actionable treatment plans with intuitive modules.
Support Quality
Brainlab delivers timely access to Elements and corresponding technical support.
Implementation Complexity
The commissioning process for Brainlab Elements using a reference beam model can be completed rapidly, with one study indicating it took a qualified medical physicist and a medical physics resident one day. The software is designed for easy setup and usage.
Evidence Base
Studies have evaluated the dosimetric performance of Brainlab Elements for Stereotactic Radiosurgery (SRS) plans, comparing different versions and algorithms. Research indicates that newer versions, with optimized tools, can generate clinically acceptable plans comparable to manually optimized ones, with improved QA results and reduced planning time. The Monte Carlo (MC) dose calculation algorithm in Brainlab Elements has demonstrated reliable accuracy across heterogeneous and small field conditions. Comparisons between Brainlab Elements' Voxel Monte Carlo (VMC) and other algorithms like Acuros XB (AXB) have shown that VMC tends to have closer agreement with measurements for brain SRS, especially for smaller targets. A cross-platform workflow for cumulative-dose-aware re-irradiation in brain metastases using Brainlab Elements has been reported as feasible and clinically actionable. End-to-end verification tests have been successfully performed for Brainlab Elements cranial vascular modules, showing high accuracy.
Physician Tip

When using (Elements) Dose Review for re-irradiation cases, actively utilize its cumulative dose assessment features to visualize summed doses across previous treatments and planning systems. This can help in prospectively constraining previously irradiated foci as organs-at-risk during optimization, thereby reducing unintended dose to healthy tissue and mitigating the risk of radiation necrosis. Leverage the dose comparison and summation capabilities to thoroughly evaluate plan alternatives and ensure optimal target coverage while sparing critical structures. For small targets, be aware of potential dosimetric differences between various calculation algorithms and consider the Voxel Monte Carlo (VMC) algorithm's closer agreement with measurements. The multi-platform flexibility allows for convenient review and planning on various devices, enhancing workflow efficiency.

(Elements) Dose Review is part of the Brainlab Elements suite, which is designed for seamless integration with other Brainlab platforms like Curve™ Image Guided Surgery and Buzz® Digital O.R. It can import and process DICOM image sets and output DICOM RT dose plans, facilitating communication with linear accelerators. The system also supports cross-platform workflows, allowing for the import of prior RT-DOSE information from other planning systems for comprehensive cumulative dose analysis.

Details

Category Oncology AI
Pricing Contact for pricing
DeploymentOn-premise, Cloud-based (Quentry® for collaboration)
Mobile App1
Compliance
BAA AvailableUnknown
HIPAA Compliant Yes AI-estimated
FDA Status Cleared AI-estimated
Integrations
EHR Not specified
Specialties Oncology

FDA clearance history

This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.

Decision dateNumberName as listed by FDA
2025-06-17K250440 510(k)(Elements) Dose Review

Ratings & Reviews

No reviews yet. Be the first to review this tool!

Rate (Elements) Dose Review

Clinical Value
Ease of Use
Integration
Support & Docs
Value for Money
No press coverage or publications on file yet. Know of some? Suggest an edit →

Videos

Product demos, reviews, and walkthroughs for (Elements) Dose Review.

View all on YouTube

Frequently Asked Questions

(Elements) Dose Review is part of the Brainlab Elements suite, which leverages AI for tasks such as tumor segmentation and dose optimization in radiation treatment planning. This AI integration aims to enhance the accuracy and speed of contouring and dose optimization, ultimately improving patient outcomes in stereotactic, conformal, and Linac-based radiation treatments.
(Elements) Dose Review provides thorough dose-to-target and dose-to-critical-structures models for comprehensive plan review and comparison. It contains features for reviewing isodose lines, dose-volume histograms (DVHs), and performing dose comparisons and summations.
Brainlab RT Elements (4.5), which includes (Elements) Dose Review, received FDA clearance on June 17, 2025, as a Class II medical device under regulation 21 CFR 892.5050. As such, it must comply with all FDA requirements, including registration and listing, labeling, medical device reporting, and good manufacturing practice requirements.
While AI systems in brain tumor radiotherapy show strong performance, approximately one-quarter of AI-generated plans may require manual clinician modification. Additionally, there have been instances where the Pencil Beam algorithm on the GPU in earlier versions of Brainlab RT Elements could lead to incorrect dose distribution calculations under specific circumstances, with deviations potentially exceeding 10%.
Alternatives to Brainlab Elements for oncology treatment planning include other treatment planning systems that utilize different dose calculation algorithms, such as Varian Eclipse with its Acuros XB (AXB) algorithm. Other treatment options for stereotactic radiosurgery (SRS) of multiple brain metastases include GammaKnife, and Volumetric Arc Therapy (VMAT) calculated with conventional optimizers or Varian HyperArc solution.
(Elements) Dose Review, in conjunction with (Elements) Retreatment Review, allows for the preparation and analysis of subsequent treatments by providing a 3D visualization of all previously treated and new metastases. It also offers review options for the summed dose of previous treatment plans, which is crucial for managing cumulative dose and avoiding hotspots in re-irradiation scenarios.
Brainlab offers flexible and scalable business models for RT Elements, allowing facilities to access the software based on their evolving needs. However, specific pricing details are not publicly disclosed, and interested parties are advised to contact a sales representative.

Related Tools

VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
Spectrum Dynamics Medical
Oncology AI
The VERITON CT 400 Series is a digital SPECT/CT system with a 360-degree gantry and 12 swiveling CZT detectors, offering high sensitivity and quantitative accuracy for a wide range of nuclear medicine applications, including advanced theranostics imaging.
syngo.via MI Workflows, syngo MBF
Siemens Medical Solutions USA
Cardiology AI
syngo.via MI Workflows, syngo MBF is an intelligent, integrated imaging software that helps address the challenges of interpreting, managing, and sharing complex data from molecular imaging scanners, providing automated workflows and advanced visualization for various clinical applications.
syngo.via MI WorkFlows, Scenium, syngo MBF
Siemens Medical Solutions USA
Cardiology AI
syngo.via MI Workflows, Scenium, and syngo MBF are medical diagnostic post-processing applications for viewing, manipulation, quantification, analysis, and comparison of PET or nuclear-medicine functional data with CT or MR anatomical data across timepoints, supporting disease management and radiotherapy treatment planning by trained healthcare professionals.
BIOGRAPH One
Siemens Healthineers AG
Oncology AI
BIOGRAPH One is a second-generation PET/MR scanner designed to transform PET/MR image quality for a new era, combining high PET precision with powerful MR performance. It enables simultaneous visualization of organ location, function, and cellular metabolism, offering faster image acquisition times and more efficient workflows than previous generations of PET/MR scanners.
Claire™ OCT System
Perimeter Medical Imaging AI
Oncology AI
Perimeter Medical Imaging AI is a medical technology company driven to transform cancer surgery with ultra-high resolution, real-time, advanced imaging tools that address unmet medical needs.S. for intraoperative breast cancer margin assessment.
syngo.via RT Image Suite VC10
Varian Medical Systems, Inc.
Clinical Decision Support & Reference
syngo.via RT Image Suite VC10 offers advanced imaging and workflow solutions for precise and efficient radiation therapy planning.

See all Oncology AI tools →

More from Brainlab AG

(Elements) Cranial SRS
Brainlab AG
Neurology AI
Elements Cranial SRS by Brainlab AG is an advanced software for stereotactic radiosurgery planning in cranial cases, offering automated, indication-specific treatment plans with 3D visualization and advanced optimization algorithms for precise and efficient dose delivery.
(Elements) Cranial SRS w/ Cones
Brainlab AG
Neurology AI
Brainlab Elements Cranial SRS w/ Cones is an AI-powered software for precise stereotactic radiosurgery planning, offering automated workflows for cranial lesions and functional diseases.
(Elements) Retreatment Review
Brainlab AG
Neurology AI
Elements Retreatment Review is an AI-powered software by Brainlab AG that streamlines retreatment planning for multiple brain metastases by integrating prior treatment data, new scans, and AI-driven tumor segmentation for optimal decision-making.
(Elements) RT Planning Platform
Brainlab AG
Oncology AI
The Brainlab Elements RT Planning Platform is a comprehensive suite of software applications for streamlined and enhanced radiation therapy and radiosurgery treatment planning, offering advanced capabilities and automated workflows for various clinical indications. [9, 11, 12, 27]

View company profile →

Suggest an Edit → | Report an issue | Last Verified: 2026-11-03 | First Added: 2026-04-17
AI Tool Finder
AI-powered search. Results may not be comprehensive.