Overview
CardIQ Suite, developed by GE Medical Systems SCS (a GE HealthCare company), is a comprehensive post-processing application designed for advanced cardiac image analysis. It provides an integrated workflow for seamlessly reviewing calcium scoring and Coronary CT Angiography (CCTA) data. The tool leverages deep learning models for automated calcium scoring, identifying coronary calcium burden and location, and providing total and per-territory scores rapidly. It also facilitates CCTA 2D review, including cine capability for motion studies and double oblique tools for detailed visualization of coronary arteries and chambers. CardIQ Suite is intended to aid in the diagnosis and determination of treatment paths for various cardiovascular diseases by analyzing 2D or 3D CT cardiac non-contrast and angiography DICOM data.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- Deep Learning based automated Calcium Score and labeling of coronary artery territories
- Integrated workflow for seamless review of calcium scoring and CCTA data
- CCTA 2D Review with cine capability for motion studies and chamber mobility analysis
- Double oblique tools for detailed visualization of coronary vasculature
- Measurement tools for distance and Region of Interest (ROI) generation
- Ability to assign calcifications to individual coronary artery branches
- Ability to score and label calcifications found in the aorta and cardiac valves
- Plaque ID tool for visualizing and quantifying plaque burden (CardIQ Xpress 2.0 Reveal)
- Relative perfusion analysis for highlighting and quantifying hypo-dense myocardial areas (CardIQ Xpress 2.0 Reveal)
- Automated segmentation and labeling of calcifications within coronary arteries
Use Cases
- Evaluation and diagnosis of coronary artery disease
- Qualitative and quantitative assessment of heart anatomy and coronary artery vessels from CT images
- Monitoring the progression or regression of calcium in coronary arteries over time
- Aiding in the prognosis of cardiac disease
- Follow-up for stent placement, bypasses, and plaque imaging
- Functional assessment of left and right ventricular volumes, ejection fractions, and myocardial mass (with CardIQ Function Xpress)
What Physicians Need to Know
CardIQ Suite streamlines cardiac CT post-processing, allowing for rapid and automated calcium scoring and comprehensive CCTA review. The deep learning algorithms enhance consistency and accuracy in identifying and labeling coronary artery calcifications. Utilize the integrated workflow to efficiently transition between calcium scoring and CCTA review, leveraging cine capabilities for motion analysis and various rendering modes for enhanced visualization. The ability to monitor calcium progression over time can be valuable for long-term patient management and risk assessment. The tool's alignment with established guidelines for CAC testing supports its use in clinical decision-making.
GE HealthCare is working towards seamless integration of its 'AW Family' Advanced Visualization applications, including CardIQ Suite, with Sectra's enterprise imaging diagnostic application for radiology. This integration aims to enhance efficiency, enable faster workflows, and streamline the cardiology care pathway by easing the transition between applications and reducing clicks. CardIQ Suite is part of the AW Family application portfolio and is built for automation and workflow efficiency. The deep learning models used in CardIQ Suite were developed and trained based on diverse clinical datasets from a global population, spanning multiple scanner types and vendors. CardIQ Suite provides various methods for sharing results, including saving Calcium Score results and images as DICOM SR series for structured reporting and exporting individual images or results tables.
Details
| Category | Cardiology AI, Radiology & Imaging AI |
| Pricing | Unknown |
| Deployment | On-premise (integrated with CT systems) |
| Data Export | Unknown |
| Training | Unknown |
| Compliance | |
| BAA Available | Unknown |
| HIPAA Compliant | Unknown |
| FDA Status | Cleared AI-estimated |
| Integrations | |
| EHR | Not specified |
| Specialties | Cardiology, Radiology |
Support & Reliability
| Training Provided | Unknown |
What the Web Says
GE HealthCare's CardIQ Suite is a post-processing application designed for advanced cardiac image analysis, aiming to enhance clinical decision-making and workflow efficiency in diagnosing and treating cardiovascular disease. It features an automated calcium scoring algorithm that quickly identifies calcium burden and location, providing total and per-territory scores within seconds. The software also supports comprehensive review of coronary CT angiography (CCTA) data with integrated workflows and deep learning models for automated segmentation and labeling of calcifications.
Overall: MixedStrengths
- Automated calcium scoring algorithm provides quick identification of calcium burden and location.
- Integrated workflow for seamless review of calcium scoring and CCTA data.
- Deep learning models for automated segmentation and labeling of coronary artery territories and calcifications.
- Ability to assign calcifications to individual coronary artery branches and score calcifications in the aorta and cardiac valves.
- Interactive toolset for reviewing cardiac exams, including double oblique angles for tracking coronary arteries and cine capability for multi-phase data.
- Potential to significantly reduce the time needed to read coronary CT angiograms, improving productivity.
Limitations
- Limited public reviews from physicians, healthcare IT, or tech reviewers specifically for CardIQ Suite, making it difficult to ascertain widespread user experience.
- Some general GE Healthcare employee reviews on platforms like Reddit mention issues with company organization and processes, though not specific to CardIQ Suite.
- Comparisons with competitor products (e.g., Philips for vascular imaging) suggest areas where GE's offerings might be perceived as less intuitive or effective by some users, though this is for echocardiography machines and not directly CardIQ Suite.
- No specific negative feedback directly related to the functionality or performance of CardIQ Suite was found in the provided search results.
Based on reviews from: nasdaq.com, comparably.com, indeed.com, fda.gov, klasresearch.com, reddit.com, gehealthcare.com, dicardiology.com, 24x7mag.com, diagnosticimaging.com, stocktitan.net, massdevice.com, capterra.co.uk, capterra.com, g2.com
Last updated: 2026-10-30
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate CardIQ Suite
Press & Coverage
Videos
Product demos, reviews, and walkthroughs for CardIQ Suite.
Frequently Asked Questions
Compare CardIQ Suite
VS
VS
VS
VS