Vereos PET/CT
Quick answers
What is Vereos PET/CT?
Vereos PET/CT: Better care for more people Made by Philips.
Is Vereos PET/CT FDA cleared?
Yes. Vereos PET/CT is on FDA’s list of AI-enabled medical devices: 510(k) K211764, cleared August 6, 2021.
Overview
The Philips Vereos PET/CT is a groundbreaking medical imaging system, recognized as the world’s first and only fully digital PET/CT solution. It leverages proprietary Digital Photon Counting (DPC) technology, which converts light directly to a digital signal with zero analog noise, overcoming the limitations of conventional photomultiplier technology. This innovation, combined with 1:1 coupling between scintillator elements and DPC detector elements and fast Time-of-Flight (TOF) technology, significantly enhances performance.
The Vereos system offers approximately double the volumetric resolution, sensitivity gain, and quantitative accuracy compared to comparable analog systems. This leads to remarkably clear images, improved detectability and characterization of small lesions, and increased diagnostic confidence. The CT component is based on the Ingenuity CT, featuring 64- or 128-channel capabilities, iDose4 for noise reduction, and optional O-MAR for metal artifact reduction.
Furthermore, the Vereos PET/CT incorporates Artificial Intelligence (AI) through its Adaptive Reconstruction (AR) package, which uses an AI-regularized reconstruction technique to produce images with consistent and reduced noise levels. The system is designed for efficient workflows, faster scans, and reduced PET dose, contributing to an enhanced patient experience. It integrates with Philips IntelliSpace Portal for advanced visualization, review, and analysis.
Reviewed by Pouyan Golshani, MD — Interventional Radiologist
Key Features
- Digital Photon Counting (DPC) Technology
- 1:1 Crystal-to-Detector Coupling
- Fast Time-of-Flight (TOF) Technology
- 64- or 128-channel CT System
- iDose4 for Noise Reduction
- O-MAR (Optional) for Metal Artifact Reduction
- iPatient Personalized Workflow
- Adaptive Reconstruction (AR) with AI
- IntelliSpace Portal Integration for Advanced Visualization
- Ambient Experience for Patient Comfort
Use Cases
- Oncology: Detecting, localizing, diagnosing, staging, re-staging cancer
- Oncology: Monitoring therapy response for various cancers
- Cardiology: Assessing myocardial perfusion and function
- Neurology: Diagnosing and monitoring neurological diseases
- Small lesion detection and characterization
- Therapy planning and follow-up
What Physicians Need to Know
For optimal use of the Vereos PET/CT, leverage its digital photon counting technology to enhance small lesion detection in oncology and neurology, and to reduce radiopharmaceutical dose in cardiology. Utilize the integrated IntelliSpace Portal for advanced visualization and analysis, especially for complex cases across different clinical areas. Take advantage of the faster scan times to improve patient throughput and comfort, particularly for patients who may have difficulty holding a position for extended periods. Regularly review and adjust CT acquisition parameters and conversion factors, confirming them before use, as they can be affected by specific scan parameters like kVp changes or reconstruction filters. Ensure proper maintenance and inspect for damages after cleaning to maintain system integrity.
The Vereos PET/CT seamlessly integrates with Philips IntelliSpace Portal for comprehensive image review and analysis in oncology, neurology, and cardiology. It supports standard DICOM data exchange for modality worklist, storage, and query/retrieve functions, facilitating interoperability with other systems. The system also allows for the fusion of CT and PET images using Philips fusion viewer Image Fusion software, which is valuable for therapeutic planning. Additionally, the Web Collaborator tool enables easy sharing of images and findings with colleagues and referring physicians.
Details
| Category | Oncology AI, Radiology & Imaging AI |
| Pricing | Unknown |
| Deployment | On-premise |
| Compliance | |
| BAA Available | Unknown |
| HIPAA Compliant | Unknown |
| FDA Status |
Cleared FDA-listed The Philips Vereos PET/CT system received 510(k) clearance from the U.S. Food and Drug Administration (FDA) to market its digital PET/CT system in the United States in 2013. The system is a diagnostic imaging device that combines Positron Emission Tomography (PET) and X-ray Computed Tomography (CT) systems. It is intended for detecting, localizing, diagnosing, staging, re-staging, and follow-up for monitoring therapy response of various diseases in oncology, cardiology, and neurology. |
| Integrations | |
| EHR | Not specified |
| Specialties | Nuclear Medicine, Oncology, Radiology |
Support & Reliability
FDA clearance history
This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.
| Decision date | Number | Name as listed by FDA |
| 2021-08-06 | K211764 510(k) | Vereos PET/CT |
Ratings & Reviews
No reviews yet. Be the first to review this tool!
Rate Vereos PET/CT
Videos
Product demos, reviews, and walkthroughs for Vereos PET/CT.
Philips Vereos Digital PET/CT - Hear From Early Adopters
Philips Healthcare
Philips Vereos Digital PET/CT Early Adopter Katherine Binzel, PhD
Philips Healthcare
Vereos Digital PET/CT Philips - Primeiro e único PET/CT digital do mundo
Philips Brasil
Philips Vereos Digital PET/CT ქირურგიის ეროვნულ ცენტრში.
Tamuna Chechelashvili
Philips Vereos Digital PET/CT Customer Testimonial from Dr. Jay Kikut
Philips Healthcare








