Genius AI Detection 2.0 with CC-MLO Correlation

by Hologic  · Based in United States → — Empowering Your Genius With Ours
Oncology Radiology

FDA Cleared
Regulatory Status Disclosed

Quick answers

What is Genius AI Detection 2.0 with CC-MLO Correlation?

Genius AI Detection 2.0 with CC-MLO Correlation: Empowering Your Genius With Ours Made by Hologic.

Is Genius AI Detection 2.0 with CC-MLO Correlation FDA cleared?

Yes. Genius AI Detection 2.0 with CC-MLO Correlation is on FDA’s list of AI-enabled medical devices: 510(k) K230096, cleared May 23, 2023.

Overview

Hologic Genius AI Detection 2.0 with CC-MLO Correlation is a computer-aided detection and diagnosis (CADe/CADx) software device designed to assist radiologists in interpreting digital breast tomosynthesis (DBT) images for breast cancer screening. It utilizes deep learning networks to identify and mark regions of interest, including soft tissue densities (masses, architectural distortions, and asymmetries) and calcifications. The 2.0 version offers improved specificity by reducing false positive marks compared to previous versions. A key feature is the CC-MLO Correlation, which helps interpreting physicians find pairs of marks that correspond to the same lesion in both craniocaudal (CC) and mediolateral oblique (MLO) views, enhancing diagnostic accuracy and workflow efficiency.

The software provides confidence scores for detected lesions and an overall case score for the entire tomosynthesis exam, aiding in the assessment of findings and case prioritization. It integrates with Hologic’s 3D Mammography™ systems and compatible review workstations, allowing for concurrent reading and optimized workflow. The system is designed to support radiologists in making faster and more confident decisions in breast cancer detection.

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Key Features

  • Deep learning AI algorithm for breast cancer detection
  • Automated lesion detection and marking on DBT images
  • CC-MLO Correlation feature for linking lesions across orthogonal views
  • Identification of soft tissue densities (masses, architectural distortions, asymmetries) and calcifications
  • Confidence scores for individual lesions and overall case scores
  • Reduced false positive marks compared to previous versions
  • Integration with Hologic 3D Mammographyu2122 systems and SecurViewu00ae 12.0 software
  • Support for concurrent reading workflow
  • Compatibility with standard and high-resolution tomosynthesis images, including 3DQuorumu2122 SmartSlices
  • Tools for case prioritization and workflow optimization

Use Cases

  • Aiding radiologists in breast cancer screening and diagnosis
  • Enhancing diagnostic accuracy in digital breast tomosynthesis interpretation
  • Improving workflow efficiency by prioritizing cases and reducing reading time
  • Providing decision support for identifying suspicious breast lesions
  • Facilitating concurrent reading of tomosynthesis images
  • Supporting early detection of breast cancer

What Physicians Need to Know

Key Capabilities
Genius AI Detection 2.0 identifies and marks regions of interest (soft tissue densities, calcifications) in Digital Breast Tomosynthesis (DBT) exams. It provides confidence scores for certainty of findings and a case score. The CC-MLO Correlation feature helps physicians find pairs of marks that correspond to the same lesion in two orthogonal views (CC and MLO). It offers a high sensitivity of 94% and significantly reduces false positive marks by over 50% compared to the previous version. The software functions concurrently during image review, overlaying marks on potential abnormalities. It supports all Hologic image types, including 3DQuorum SmartSlices.
Clinical Utility
This AI tool is designed to assist interpreting physicians in reviewing tomosynthesis images, potentially enhancing diagnostic accuracy. It aims to improve cancer detection rates and reduce false recalls. The CC-MLO Correlation feature is highly accurate in biopsied malignant cases where the same lesion is marked in both orthogonal views. It can help prioritize case review based on suspicious lesions and case scores. Studies have shown a +9% improvement in observed reader sensitivity for cancer cases when using Genius AI Detection, equating to finding approximately one additional cancer for every 10 identified by a radiologist.
Integration Options
Genius AI Detection 2.0 is designed to integrate with compatible digital breast tomosynthesis (DBT) systems. It runs on the acquisition workstation of Hologic Dimensions mammography systems without needing a separate server. The software packages CAD findings into a DICOM Mammography CAD SR object for display on DICOM-compliant review workstations. It can be viewed in SecurView 12.0 software and marks can be displayed on individual tomosynthesis slices, 3DQuorum SmartSlices, FFDM, and synthesized 2D images.
Compliance Status
Genius AI Detection 2.0 is a computer-aided detection and diagnosis (CADe/CADx) software device. It is restricted by United States federal law to sale by or on the order of a physician. It has received 510(k) Premarket Notification.
User Experience
The software overlays marks on potential abnormalities on tomosynthesis slices, functioning like an additional pair of eyes. It provides confidence scores and a case score to aid interpretation. The CC-MLO Correlation feature displays correlated marks in a specific way to indicate lesions in two orthogonal views. It offers workflow tools to enhance practice, including the ability to prioritize case review.
Evidence Base
Performance validation studies have shown that the concurrent use of Genius AI Detection software enhances the diagnostic accuracy of interpreting physicians. Studies indicate a significant reduction in false positive marks (over 50%) with Genius AI Detection 2.0 compared to its predecessor, while maintaining high sensitivity. Research has also evaluated its performance across diverse patient populations, including Asian, Black, Hispanic, and white women, finding similar algorithm performance across these groups. A retrospective analysis highlighted its ability to aid in detecting previously missed cancers and correctly localize suspicious areas.
Physician Tip

Leverage the CC-MLO Correlation feature to efficiently identify corresponding lesions across different views, potentially reducing search time. Utilize the confidence scores and case scores to help prioritize your review workflow. Be aware that while the AI provides valuable assistance, it is a tool to aid diagnosis and not a replacement for comprehensive physician interpretation. Consult with your workstation vendor regarding the specific availability and integration of all Genius AI Detection software features.

Genius AI Detection 2.0 is designed for seamless integration with Hologic's Digital Breast Tomosynthesis (DBT) systems, specifically running on the acquisition workstation of Hologic Dimensions mammography systems. It outputs DICOM Mammography CAD SR objects for display on DICOM-compliant review workstations and is viewable in SecurView 12.0 software. Compatibility with other PACS vendors for full feature display should be verified.

Details

Category Oncology AI, Radiology & Imaging AI
Pricing Unknown
DeploymentOn-premise (runs on the acquisition workstation of the mammography system)
Training Yes
Compliance
BAA Available Yes AI-estimated
HIPAA Compliant Yes AI-estimated
FDA Status Cleared FDA-listed

Genius AI Detection 2.0 is a computer-aided detection and diagnosis (CADe/CADx) software device intended to be used with compatible digital breast tomosynthesis (DBT) systems to identify and mark regions of interest including soft tissue densities (masses, architectural distortions, and asymmetries) and calcifications in DBT exams from compatible DBT systems and provide confidence scores that offer assessment for Certainty of Findings and a Case Score. It received FDA clearance for its Genius AI™ Detection technology, a deep learning-based software designed to help radiologists detect subtle potential cancers in breast tomosynthesis images. The Genius Digital Diagnostics System, powered by the company's Genius Cervical AI algorithm, also received FDA clearance in February 2024.

Integrations
EHR Not specified
Specialties Oncology, Radiology

Support & Reliability

Training Provided Yes

FDA clearance history

This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.

Decision dateNumberName as listed by FDA
2023-05-23K230096 510(k)Genius AI Detection 2.0 with CC-MLO Correlation

Ratings & Reviews

No reviews yet. Be the first to review this tool!

Rate Genius AI Detection 2.0 with CC-MLO Correlation

Clinical Value
Ease of Use
Integration
Support & Docs
Value for Money
No press coverage or publications on file yet. Know of some? Suggest an edit →

Videos

Product demos, reviews, and walkthroughs for Genius AI Detection 2.0 with CC-MLO Correlation.

No videos found. Search YouTube directly

View all on YouTube

Frequently Asked Questions

Hologic's Genius AI Detection 2.0 solution uses deep learning AI to analyze 2D and DBT images, identifying potential abnormalities and correlating marks between CC and MLO views. This aims to improve the accuracy of breast screening results and reduce false positive marks, ultimately aiding radiologists in their diagnostic performance.
The system offers several benefits, including a reported 9% improvement in observed reader sensitivity for cancer cases, equating to approximately one additional cancer found for every 10 identified by a radiologist. It also significantly reduces false positive marks per case by over 70% compared to previous CAD solutions, and provides workflow efficiencies like automated pre-reporting and patient worklist integration.
Genius AI Detection 2.0 does not identify all suspicious areas for cancer and may not mark all cancerous lesions. It is not currently designed to track changes from prior mammograms or detect conditions like skin thickening, nipple retractions, asymmetric breast tissue, or tubular density/solitary dilated ducts. Additionally, its diagnostic performance has not been evaluated for mammograms from patients with breast implants or partial views.
Genius AI Detection 2.0 is a software-only device classified as Class II and is intended to be used with compatible digital breast tomosynthesis (DBT) systems. It has received 510(k) premarket notification clearance from the FDA, indicating it is safe and effective for detecting soft lesions and calcifications in tomosynthesis exams.
While the prompt does not specify direct alternatives by name, Hologic has been a leader in breast tomosynthesis technology. Studies have shown that deep learning-based AI algorithms like Genius AI Detection 2.0, when applied to DBT images, significantly outperform traditional machine learning CAD algorithms for synthetic 2D mammographic images in terms of AUC, sensitivity, and specificity.

Related Tools

VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
Spectrum Dynamics Medical
Oncology AI
The VERITON CT 400 Series is a digital SPECT/CT system with a 360-degree gantry and 12 swiveling CZT detectors, offering high sensitivity and quantitative accuracy for a wide range of nuclear medicine applications, including advanced theranostics imaging.
syngo.via MI Workflows, syngo MBF
Siemens Medical Solutions USA
Cardiology AI
syngo.via MI Workflows, syngo MBF is an intelligent, integrated imaging software that helps address the challenges of interpreting, managing, and sharing complex data from molecular imaging scanners, providing automated workflows and advanced visualization for various clinical applications.
syngo.via MI WorkFlows, Scenium, syngo MBF
Siemens Medical Solutions USA
Cardiology AI
syngo.via MI Workflows, Scenium, and syngo MBF are medical diagnostic post-processing applications for viewing, manipulation, quantification, analysis, and comparison of PET or nuclear-medicine functional data with CT or MR anatomical data across timepoints, supporting disease management and radiotherapy treatment planning by trained healthcare professionals.
BIOGRAPH One
Siemens Healthineers AG
Oncology AI
BIOGRAPH One is a second-generation PET/MR scanner designed to transform PET/MR image quality for a new era, combining high PET precision with powerful MR performance. It enables simultaneous visualization of organ location, function, and cellular metabolism, offering faster image acquisition times and more efficient workflows than previous generations of PET/MR scanners.
Claire™ OCT System
Perimeter Medical Imaging AI
Oncology AI
Perimeter Medical Imaging AI is a medical technology company driven to transform cancer surgery with ultra-high resolution, real-time, advanced imaging tools that address unmet medical needs.S. for intraoperative breast cancer margin assessment.
syngo.via RT Image Suite VC10
Varian Medical Systems, Inc.
Clinical Decision Support & Reference
syngo.via RT Image Suite VC10 offers advanced imaging and workflow solutions for precise and efficient radiation therapy planning.

See all Oncology AI tools →

More in the Genius AI Detection line

Genius AI Detection Genius AI Detection 2.0 with CC-MLO Correlation (this page)

More from Hologic

Genius AI Detection
Hologic
Oncology AI
Hologic's Genius AI Detection is a deep learning-based software that assists radiologists in the early detection of breast cancer by identifying suspicious lesions in breast tomosynthesis images, reducing false positives, and optimizing workflow.
Genius Digital Diagnostics System with the Genius Cervical AI algorithm
Hologic
OB/GYN AI
M1000 IMAGECHECKER
Hologic
Oncology AI
Quantra
Hologic
Oncology AI
Hologic Quantra 2.

View company profile →

Suggest an Edit → | Report an issue | Last Verified: 2026-11-08 | First Added: 2026-04-18