Avicenna.AI is a medical AI company founded in 2018, specializing in AI-based solutions for radiology. The company develops deep learning algorithms to identify, detect, and quantify critical pathologies from CT images, aiming to empower healthcare professionals, accelerate therapeutic decision-making, and improve patient outcomes. Its CINA suite of AI tools is designed to seamlessly integrate into existing clinical workflows, providing rapid and reliable insights for various medical emergencies and incidental findings.

CINA-CSpine is a key product within this portfolio, specifically developed as a triage and notification software for the analysis of cervical spine CT images. It utilizes artificial intelligence to detect suspected acute cervical spine fractures on non-enhanced neck CT scans, automatically flagging potential fractures and notifying the care team. This helps radiologists determine if the spine is compromised, reducing the risk of missed injuries and facilitating quicker interventions for improved patient prognosis.

Reviewed by Pouyan Golshani, MD — Interventional Radiologist

Key Features

  • Detects acute cervical spine fractures on non-enhanced neck CT scans
  • Triage tool to automatically flag potential fractures
  • Assists radiologists in identifying compromised spines
  • Provides notifications for cases with suspected findings
  • Integrates seamlessly with standard reading environments (PACS, RIS)
  • Supports global healthcare data standards (DICOM, HL7, FHIR)
  • Offers cloud-based, local dedicated hardware, or local virtualized deployment
  • Validated on multi-center, multi-national, and multi-vendor datasets
  • Achieved 90.3% sensitivity and 91.9% specificity in validation studies
  • Designed for use on patients over 18 years old

Use Cases

  • Accelerated diagnosis of cervical spine fractures in emergency settings
  • Improved patient outcomes through quicker interventions for spinal injuries
  • Minimizing diagnostic errors and reducing the likelihood of missed fractures
  • Prioritization of urgent cases in emergency and trauma care workflows
  • Enhancing radiology workflow efficiency and reducing interpretation time
  • Supporting therapeutic decision-making processes for better quality of care

What Physicians Need to Know

DICOM Support & Standards
CINA-CSpine complies with DICOM (Digital Imaging and Communications in Medicine) standards (NEMA PS 3.1 - 3.20). It integrates via standard DICOM into existing PACS and worklists.
PACS Integration Method
The tool integrates into standard reading environments (PACS), RIS (Radiological Information System), via AI marketplaces or distribution platforms, and can function as a standalone third-party application. It automatically analyzes qualifying cervical CT scans without manual trigger, flagging suspected fracture cases in the worklist before interpretation.
Reading Room Workflow Impact
CINA-CSpine is designed to seamlessly integrate into radiologists' workflows, automatically triggering and reporting algorithm results through existing systems. It flags suspected fractures from C1 to C7, pushing these cases to the top of the worklist for faster treatment. The radiologist always makes the final decision.
AI Model Architecture (deep learning approach)
CINA-CSpine utilizes deep learning algorithms to identify suspected positive findings compatible with acute cervical spine fractures. It employs a deep learning model trained end-to-end on 1,338 cases from the US and France. The development involved a cascade of fully 3D, task-focused U-Net CNNs.
Processing Speed (per study)
The mean time-to-notification for all included cases (n=328) was estimated to be 2.9 minutes.
FDA Clearance Pathway (510k/De Novo)
CINA-CSpine received U.S. FDA 510(k) clearance.
Supported Modalities (CT/MRI/X-ray/US)
CINA-CSpine is designed for use with non-contrast CT scans of the cervical spine.
Sensitivity & Specificity Data
In a validation study on over 300 non-contrast CT scans, CINA-CSpine achieved a sensitivity of 90.3% and a specificity of 91.9%. These results were compared against the consensus of three U.S.-board certified senior radiologists.
RSNA/ACR Validation
The AI application for detecting acute cervical spine fractures demonstrated high diagnostic performance on multicenter, multinational, and multivendor data. While winning algorithms from the 2022 RSNA AI challenge were evaluated on a multi-institutional and multinational expert-labeled dataset, performance assessment was limited to case-level classification.
Physician Tip

CINA-CSpine is a triage and notification tool that flags suspected cervical spine fractures on non-enhanced neck CT scans, helping to prioritize cases. It is not designed to detect vertebral compression fractures. The tool integrates directly into existing PACS and worklists, automatically analyzing scans and alerting radiologists to potential fractures. While it provides rapid detection and prioritization, the radiologist remains responsible for the final diagnosis. The tool has demonstrated high sensitivity and specificity in detecting acute cervical spine fractures.

CINA-CSpine integrates with standard DICOM protocols, allowing seamless incorporation into existing PACS and RIS. It can also be deployed via AI marketplaces or as a standalone application. The system automatically processes qualifying CT scans without requiring manual triggers, and it sends notifications to the worklist application to flag suspected cases.

Details

Category Radiology & Imaging AI, Triage & ER/ICU AI
Pricing Unknown
DeploymentOn-premise or cloud-based, integrates directly with PACS and RIS.
Mobile AppAvicenna Research (for research studies, not CINA products), Avicenna Microscope (for cancer cell image analysis, not CINA products)
Compliance
BAA AvailableUnknown AI-estimated
HIPAA Compliant Yes AI-estimated
FDA Status Yes AI-estimated
Integrations
EHR Not specified
Specialties Emergency Medicine, Neurosurgery, Radiology

Support & Reliability

FDA clearance history

This product’s FDA authorization. From FDA’s list of AI-enabled medical devices; each number links to FDA’s record.

Decision dateNumberName as listed by FDA
2024-09-12K240942 510(k)CINA-CSpine

Ratings & Reviews

No reviews yet. Be the first to review this tool!

Rate CINA-CSpine

Clinical Value
Ease of Use
Integration
Support & Docs
Value for Money
No press coverage or publications on file yet. Know of some? Suggest an edit →

Videos

Product demos, reviews, and walkthroughs for CINA-CSpine.

No videos found. Search YouTube directly

View all on YouTube

Frequently Asked Questions

CINA-CSpine is an AI-powered triage and notification tool designed to detect suspected acute cervical spine fractures on non-contrast CT scans in adults. It integrates into existing PACS and worklist systems via standard DICOM, automatically analyzing qualifying CTs and flagging suspected fractures before the radiologist opens the case, delivering a preview with the identified fracture.
CINA-CSpine is designed to flag suspected non-displaced fracture lines and displaced fracture fragments in the cervical vertebrae (C1-C7) on non-contrast CT scans. It is not designed to detect vertebral compression fractures.
Yes, CINA-CSpine has received FDA 510(k) clearance in the US and is CE-marked as a Class IIb medical device under European Regulation (EU) 2017/745.
In validation testing, CINA-CSpine demonstrated an overall sensitivity of 90.3% and a specificity of 91.9% for cervical spine fractures. This was based on over 300 non-contrast CT scans from various sources and scanner models.
While Avicenna.AI offers CINA-CSpine, other companies provide AI solutions for radiology. Some of the main alternatives in the AI radiology market include Aidoc, Viz.ai, RapidAI, Brainomix, and Qure.ai.
Avicenna.AI generally offers CINA-CSpine through a subscription-based pricing model. The cost is typically based on factors such as the number of installations or the number of users.

Related Tools

RADIN Health
RADIN Health
Clinical Decision Support & Reference
RADINA is an AI-powered platform by RADIN Health designed to optimize radiology workflows, enhance diagnostic accuracy, and streamline reporting.
VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
Spectrum Dynamics Medical
Oncology AI
The VERITON CT 400 Series is a digital SPECT/CT system with a 360-degree gantry and 12 swiveling CZT detectors, offering high sensitivity and quantitative accuracy for a wide range of nuclear medicine applications, including advanced theranostics imaging.
VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364)
Spectrum Dynamics Medical
Radiology & Imaging AI
The VERITON-CT 300 Series Digital SPECT/CT System is a new-generation SPECT/CT system that wraps 360° around the patient's body contour for a personalized exam, utilizing 12 digital CZT detectors for accurate and confident diagnoses.
ACUSON Sequoia Diagnostic Ultrasound System, ACUSON Sequoia Select Diagnostic Ultrasound System, ACUSON Origin Diagnostic Ultrasound System, ACUSON Origin ICE Diagnostic Ultrasound System
Siemens Medical Solutions, USA
Cardiology AI
Siemens Healthineers offers advanced AI-powered ultrasound systems, including the ACUSON Origin for comprehensive cardiovascular care and the ACUSON Sequoia for high-performance general imaging with BioAcoustic™ technology.
syngo.via MI Workflows, syngo MBF
Siemens Medical Solutions USA
Cardiology AI
syngo.via MI Workflows, syngo MBF is an intelligent, integrated imaging software that helps address the challenges of interpreting, managing, and sharing complex data from molecular imaging scanners, providing automated workflows and advanced visualization for various clinical applications.
MAGNETOM Vida, MAGNETOM Sola, MAGNETOM Lumina, MAGNETOM Altea
Siemens Medical Solutions USA
Radiology & Imaging AI
Siemens Medical Solutions USA, Inc. provides innovative medical technologies and services that enhance healthcare delivery, specializing in advanced medical imaging systems like the MAGNETOM MRI series.

See all Radiology & Imaging AI tools →

More from Avicenna.AI

CINA
Avicenna.AI
Neurology AI
CINA is an AI-powered suite of tools developed by Avicenna.AI to enhance the detection and triage of critical conditions in CT scans, aiming to improve diagnostic accuracy and patient outcomes.
CINA CHEST
Avicenna.AI
Cardiology AI
AI, designed for the rapid detection and prioritization of Pulmonary Embolism (PE) and Aortic Dissection (AD) on CT angiography scans.
CINA-ASPECTS
Avicenna.AI
Neurology AI
CINA-ASPECTS by Avicenna.
CINA-iPE
Avicenna.AI
Radiology & Imaging AI
AI that detects unsuspected pulmonary embolisms on CT scans performed for other health conditions, enabling radiologists to initiate early treatment and prevent missed diagnoses.

View company profile →

Suggest an Edit → | Report an issue | Last Verified: 2026-11-03 | First Added: 2026-04-17